WINDOW INSTALLATION
_____________________________________
Window Opening Measurements:
•
30” min to 40” max. opening width.
•
20” Min. opening height.
_____________________________________
Electrical Requirements
_____________________________________
Recommended Grounding Method
This air conditioner must be grounded. This air
conditioner is equipped with a power supply
cord having a grounded 3 prong plug. To
minimize possible shock hazard, the cord must
be plugged into a mating, grounded 3 prong
outlet, grounded in accordance with all local
codes and ordinances. If a mating outlet is not
available, it is the customer’s responsibility to
have a properly grounded 3 prong outlet
installed by a qualified electrical installer.
It is the customer’s responsibility:
•
To contact a qualified electrical
installer.
•
To assure that the electrical
installation is adequate and in
conformance with National Electrical
Code, ANSI/NFPA 70- latest edition,
and all local codes and ordinances.
Copies of the standards listed may be obtained
from:
National Fire Protection Association
One Batterymarch Park
Quincy,
MA
02269
_____________________________________
Power Supply Cord
_____________________________________
NOTE:
Your unit’s device may differ from the
ones shown.
This room air conditioner is equipped with a
power supply cord required by UL. This power
supply cord contains state-of-the-art
electronics that sense leakage current. If he
cord is crushed, the electronics detect leakage
current and power will be disconnected in a
fraction of a second.