STS11 Touchscreen Programmable Thermostat
80
Minimum Off-Timer
The Thermostat has built-in compressor
protection (minimum- off timer) that prevents
the compressor from restarting too early after
a shutdown.
The minimum-off timer is activated after the
compressor turns off.
If there is a call or set point change during
the minimum-off timer, the thermostat shows
Wait in display.
When the minimum-off timer expires, Cool
On or Heat On
a
appears solidly in the display
and the compressor and fan turn on.
a
Heat Pump only.
Room
Running As SCHED
Set To
SYSTEM
COOL
MORE
SCHED
HOLD
CLOCK SCREEN
AUTO
FAN
PM
WED
Wait
STS11 Touchscreen Programmable Thermostat
81
Special Heat Pump Operation
Heat Pump Indication (Requires
24VAC Common Connection)
“E5” indication is located in the screen of the
thermostat. It is only visible when lighted.
When the L terminal is wired to an
equipment monitor, this is operational in the
HEAT, OFF, COOL or AUTO positions.
When the “E5” is illuminated call for service.
See Fig. 26.
Fig. 26. L terminal switch to R (power)
side of system transformer.
Operating Sequence
The thermostat energizes specific
terminal(s), depending on the demand for
heating, cooling or fan. The thermostat
screen shows the time, inside temperature,
system and fan selections. Additional
indicators are shown when the heating,
cooling or fan is energized. See Tables 7 - 9
for specification information.