950-0207revA - 8 - November 27, 2013
REMOTE CONTROL FUNCTIONS
Note: Be sure there are no obstructions between the remote control and the receiver. Remote control
units are interchangeable, and are not assigned to a particular indoor unit. Indoor controller will beep
each time it receives a command from the remote control. Keep the remote control away from moisture
and excessive heat.TIP: Each remote will control any or all the indoor units.
ON/OFF
-Turns the unit on or off. There is a 3 minute compressor delay when the unit is turned on.
MODE
– Pressing the MODE button will select between AUTO, COOL, DRY, FAN, or HEAT (for Heat
Pump units only).
AUTO mode - Set point temperature will not be shown on the remote control display and
cannot be changed. Temperature is automatically set to 68 °F to 77 °F and will switch between
COOL, HEAT or FAN mode to maintain the temperature. If the temperature goes below 68 °F
the unit will switch to HEAT mode. If the temperature goes above 77 °F unit switches to COOL
mode. If temperature is in between the temperatures it runs in the FAN mode.
On rare occasions while running in the AUTO mode with other zones activated there may be
an “E7” error code. “E7” error code occurs when 2 or more units are set to run in different
modes, such as HEAT and COOL. In the AUTO mode the unit automatically switches between
HEAT, COOL or FAN. If other zones are set to HEAT or COOL while the AUTO is running in
an opposite mode an “E7” will occur. To rectify this condition you must set all the indoor units
to the same mode, either HEAT or COOL, or leave the unit alone and when the temperature
returns to the point where the unit switches back to the correct mode (as the other indoor units)
and all zones are in the HEAT or COOL mode, it will clear itself and begin to run again.
COOL mode
– Unit cools room to set point temperature. Set point temperature can be set from
61 °F to 86 °F. Outdoor unit will operate in outside temperatures of +4 to +118 ºF in the cooling
mode. Indoor fan does not turn off in the cooling mode when temperature set point has been
satisfied. It will continue to run to keep the room temperature consistent.
HEAT mode (for Heat Pump units only) - Unit heats room to set point temperature. Set point
temperature can be set from 61 °F to 86 °F. Outdoor unit will operate in outside temperatures
of -5 ºF to +75 ºF in the heating mode. Indoor fan will turn off in heating mode when
temperature set point has been satisfied.
ON/OFF: Turns unit on or off.
▲/▼: Raise, Lower set point of temperature
or timer.
FAN: Set fan speed, hi, med, lo, auto.
MODE
–
Select between AUTO, COOL,
DRY, FAN, or HEAT.
TIMER: Set timer on /off time.
FUNCTION: Switchover among the functions
of Louver Swing, Sleep, Turbo, Energy Save
(N/A), E-heater (N/A), Dry, Quiet (N/A) and
Blow.
SHIELD: All buttons are disabled. The unit is
controlled by central control.
º
F or
º
C
– Select
º
F or
º
C (see manual
950-0210 on page 4)
LOCK KEY PAD
– No changes can be made
(see manual 950-0210 on page 11)
KEY PAD FUNCTIONS