Sistemi elettronici
di Aperture Porte e Cancelli
Fig. 14
Fig. 15
Mechanical limit switch
Inductive limit switch
4/30
7. LIMIT SWITCH ADJUSTMENT
7.1.
In order to install and adjust the limit switch in opening, follow
the below mentioned instructions (Fig. 13):
- Take the gate to complete opening,
- Place the small plate on the gear rack so that the limit switch is
(small lever in case of mechanical limit switch (Fig. 14); small
pointers placed on the upper part in case of inductive limit switch
(Fig. 15)) in corrispondence of pointX which is placed 50 mm
from the folded side of the small plate (fig. 16) and fix it with the
delivered screws (Fig. 17).
7.2.
In order to install and adjust the limit switch in closing, follow
the below mentioned instructions (Fig. 13):
- Take the gate to complete closing
- Place the small plate on the gear rack so that the limit switch is
in corrispondence of pointX which is placed 50 mm from the
folded side of the small plate (fig. 16) and fix it with the delivered
screws (Fig. 17).
Fig. 13
Limit switch in closing
Limit switch in opening
Fig. 17
50 mm
X
Fig. 16
Position in which must be the spring
(mechanical limit switch) or the
pointer (inductive limit switch)
Adjusting the trimmer for braking, placed on the electronic
control unit, it is possible to make the gate stop on the desired
position.
Fig. 18
N F
8. GROUNDING (Fig. 18)
REV 00 - 11/2007
cod. 67410328