Chapter
11
Electrical Information
Caution: ELECTRICAL SHOCK HAZARD. A Volt/Ohm Meter will be necessary for some troubleshooting and
subsequent corrective actions. The following procedures expose the technician to high voltage and electrical shock
hazard. Only attempt this if you are a qualified electrician and surrounding conditions are safe.
Caution: Always allow slack in electrical cables. Allow the cable to enter or leave from the strain relief in a straight
manner for several inches to ensure proper connection, to relieve stress to the cable and fitting, and to allow ease
of detachment and reattachment for maintenance or replacement. If electrical cables are pulled tight causing them
to bend at the strain relief they will pull out of the strain relief causing a dangerous electrical shock condition, the
wire may break, and the strain relief will lose its watertight integrity.
Caution:
Review the “Check Off Q.C. Sheet” that accompanied this Owner's Manual and the Invoice th
at
accompanied this Ultra Whisper System to ensure that it has been configured from Sea Recovery for the appropriate
and proper DC Voltage or AC Voltage, Cycles, and Phase.
Notes:
1. A 12 VDC System will NOT function from 24 VDC Power.
2. A 24 VDC System will NOT function from 12 VDC Power.
3. An AC 50 Hz System will operate at higher than normal pressure and will over heat the Feed Pump Motor
4. An AC 60 Hz System will operate at lower than normal pressure, will produce 17% less product water than specified,
and the product water will be high in salt content if connected to a 50 Hz power source.
Remove the Front cover from the system controller to access the Main Terminal Strip and Printed Circuit Board. System
configuration, optional Accessories present, and the specific model all are contributing factors to the amount of electrical
connections required during installation. The following items are listed but may either not be present (Optional Accessory
not ordered) or may already be connected. Track each electrical wire to ensure proper connection. (*** = Optional
Accessory)
Ultra Whisper System Required Electrical Connections
Feed Pump Electric Motor
Low Pressure Transducer
High Pressure Transducer
Fresh Water Flush Pump Electric Motor
3-way Product Water Diversion Solenoid Valve
*** UV Sterilizer
*** Remote Controller
*** Soft Start
Electrical Power to the System
ELECTRICAL REQUIREMENTS
1. Amperage Notes:
Alternating Current Powered Systems:
6
5
Содержание Ultra Whisper Compact 400
Страница 2: ......
Страница 3: ...Ultra Whisper 400 600 Owner s Manual Manual PN B651380001D...
Страница 4: ......
Страница 8: ......
Страница 18: ...1 6 UltraWhisper400 600...
Страница 24: ...22 UltraWhisper400 600...
Страница 36: ......
Страница 37: ......
Страница 38: ......
Страница 48: ...46 UltraWhisper400 600...
Страница 58: ......
Страница 59: ......
Страница 60: ......
Страница 66: ...Ultra Whisper 400 600 64...
Страница 71: ...Chapter 12 Exploded Parts View 69...
Страница 81: ...79 7 8 6 4 1 3 1 2 4 9 5...
Страница 89: ...Exploded Parts View 5 11 22 17 13 2 1 16 15 12 14 20 10 19 4 16 18 21 9 7 24 6 8 3 18 5 21 23 87...
Страница 97: ...95 Exploded Parts View 6 7 5 2 3 2 4 10 5 8 9 1...
Страница 99: ...12 8 9 2 10 13 1 3 5 4 14 11 6 15 7 97...
Страница 105: ...Chapter 13 Appendix 103...
Страница 106: ......
Страница 107: ......
Страница 108: ......
Страница 109: ......
Страница 110: ......
Страница 111: ......
Страница 113: ......
Страница 118: ......
Страница 119: ......
Страница 120: ......