24
Chlorine dioxide chlorine
Bromine phenolic disinfectants
Chloramines N-chlorioisocyanurates
Hypochlorite iodine
Bromide petroleum products
Important: The use of non-authorized and/or the misuse of authorized chemicals will void your Sea Recovery
Corporation warranty! For example, DO NOT connect the S
ystem’s inlet to your ship’s potable water
system if it contains chlorinated or brominated water. These chemicals destroy the copolymer components and
the oxidants will damage the RO Membrane Element. In this situation, you can use the optional Sea Recovery
Fresh Water Flush Accessory to remove the chlorine and bromine from your ship's potable water system
before connecting the Ultra Whisper RO Desalination System.
System Safety Check
Danger: Do not perform installation, maintenance or troubleshooting procedures until you have verified the
conditions below.
The System's Feed Water Sea Cock Valve is closed.
The System's main electrical disconnect switch is OFF, LOCKED and TAGGED.
Installer Minimum Qualifications
The System's Installer must have technical expertise in the following areas:
Electrical, Electronic, Electric Motors and Circuits
Electromechanical and Mechanical Systems
Hydraulic and Liquid Pressure and Flow Systems
Piping and Plumbing Systems
Water Suction and Pressure Lines
Thru-Hull Fitting below and above water level
Warnings
Danger: ELECTRICAL SHOCK HAZARD! The Ultra Whisper RO Desalination System installation procedures
expose the installer to high voltage and potential electrical hazards. Technicians should only attempt
installation if (1) they are qualified electricians and (2) surrounding conditions are safe.
Caution: Do not attempt Installation, commissioning, troubleshooting, or repair of the Ultra Whisper RO
Desalination System unless you are proficient in the fields/functions listed within the chapter Installer Minimum
Qualifications.
Caution: The RO Membrane Element is stored in sodium bisulfite. Avoid skin and eye contact with this
packaging solution. If skin contact occurs, rinse skin thoroughly with water. If eye contact occurs, flush eyes
repeatedly with water and notify a physician immediately.
Caution: Never mount the liquid holding component above any electrical or electronic device. Extensive
damage to the electronic device will result if liquid enters device during maintenance and/or component failure.
Important: Do not over-tighten PVC fittings. If threaded pipe fittings leak after installation, remove the fitting,
clean the mating threads, apply three (3) to four (4) wraps of Teflon tape to the male threads, apply liquid
Teflon pipe sealer sparingly, and thread the parts back together. PVC fittings should be hand tightened, without
the use of a wrench.
Ultra Whisper 400-600
Содержание Ultra Whisper Compact 400
Страница 2: ......
Страница 3: ...Ultra Whisper 400 600 Owner s Manual Manual PN B651380001D...
Страница 4: ......
Страница 8: ......
Страница 18: ...1 6 UltraWhisper400 600...
Страница 24: ...22 UltraWhisper400 600...
Страница 36: ......
Страница 37: ......
Страница 38: ......
Страница 48: ...46 UltraWhisper400 600...
Страница 58: ......
Страница 59: ......
Страница 60: ......
Страница 66: ...Ultra Whisper 400 600 64...
Страница 71: ...Chapter 12 Exploded Parts View 69...
Страница 81: ...79 7 8 6 4 1 3 1 2 4 9 5...
Страница 89: ...Exploded Parts View 5 11 22 17 13 2 1 16 15 12 14 20 10 19 4 16 18 21 9 7 24 6 8 3 18 5 21 23 87...
Страница 97: ...95 Exploded Parts View 6 7 5 2 3 2 4 10 5 8 9 1...
Страница 99: ...12 8 9 2 10 13 1 3 5 4 14 11 6 15 7 97...
Страница 105: ...Chapter 13 Appendix 103...
Страница 106: ......
Страница 107: ......
Страница 108: ......
Страница 109: ......
Страница 110: ......
Страница 111: ......
Страница 113: ......
Страница 118: ......
Страница 119: ......
Страница 120: ......