background image

7

6

1100mm

485mm

720mm

Ø200

340mm

830mm

material 

Heating Capacity 

Kw output

avg emissions 

Avg Efficiency

glass door

minimum flue Height

flue dimensions

outside air Kit

warranty

weight

minimum Hearth dimensions

oVerall Zero ClearanCe boX dimensions

FRONT

SIDE

aXiS i1000iB   double Sided

*Heating capacity of the following appliances are a guide only and refers to areas with 2.4m ceilings 

and 6 or more star rated buildings. Heating output may vary depending on factors such as building 

characteristics, quality of insulation, type of firewood used and climate zone.

**See warranty pg. 29 of the manual.

***refer to pg. 8 for further details about the clearances & hearth.

2. SpecificationS

Solid steel firebox with firebricks

Up to 15-30 Squares

*

18.7kW

1.0g/kg

62%

2x Secure Swing door opening system 

4.6m 

200mm, 250mm, 300mm

recommended for well insulated homes

10 year firebrick & 5 year firebox warranty

**

180kg

Width: 1300mm Depth: 550mm (either side of firebox - 1605mm total) 

thickness: 42mm 

***

2. SpecificationS

this appliance and flue were tested with the following minimum clearances.

the axis i1000iB and Z/c box was tested in a combustible enclosure in a manner conforming to aS/nZS 

2918:2001, appendix B. the sides and rear of the wall enclosure must be no closer than

 50mm

 from the 

sides and rear of the appliance zero clearance box. The front wall of the enclosure must be made of a 

non-combustible material to a height of 

300mm

 above the appliance fascia and must extend to 

100mm

 

either side of the appliance fascia. the internal wall studs of the appliance must also be made of a non-

combustible material.  

important: mantel sHelf: 

mantel shelf and mantel upright clearance was not tested and should 

be installed as per clause 3.4.1.3 (b) of AS/NZS 2918:2018.

a minimum

 520mm

 deep X 

1100mm

 wide and 

25mm

 thick floor protector (Skamotec board or similar) 

should be used under the appliance. the floor protector/hearth should also extend a minimum 

1220mm

 

wide X 

700mm

 deep X 

25mm

 thick (Skamotec board or similar) and must be used in front of the 

appliance (see joint AS/NZS 2918:2018 3.3.2).The floor protector must extend 

700mm

 in front of the 

fuel loading door and be placed centrally in the 

1220mm 

width.

The appliance is required to be installed on 30mm high spacers inside the zero clearance box between 

the appliance and the base of the zero clearance box.

please note

:

 a minimum 50mm air gap must be maintained around the outer triple skin flue in the 

ceiling of the enclosure.

clearances & Hearth- axis i1000iB SinGle Sided

siDE

Front

toP

*all diagrams are not to scale

50MM air gaP

Min 1220MM

520MM

700MM

50MM air gaP

300MM

non-CoMBustiBlE

non-CoMBustiBlE 

stuD

non-CoMBustiBlE 

MatErial

non-CoMBustiBlE 

MatErial

50MM air gaP

25MM

Floor ProtECtor

(Must BE a Fully 

suPPortED BasE)

Min 100MM

MiniMuM

50MM  

air gaP FroM 

CoMBustaBlEs

Min 100MM

TOP

Dimensions of the firebox: 994mm Width; 589.5mm Height; 506.5mm Depth  

Содержание AXIS I1000 IB ZERO CLEARANCE

Страница 1: ...ALL GUIDE 4 ZERO CLEARANCE ASSEMBLY 5 install guide 6 OPERATION MAINTENANCE 7 test report 8 Warranty I1000 I1000DS IB ZERO CLEARANCE Installation User guide AXIS NOTICE TO INSTALLER These instructions must be left with the owner who should keep them for future use ...

Страница 2: ... in order to become acquainted with the installation methods specific to your fireplace It is recommended that this fireplace be installed by a qualified and licensed trades professional You will find in this guide the answers to most of your questions should you require further assistance we recommend you contact your retailer Before igniting your fireplace for the first time please carefully rea...

Страница 3: ...he distributor and manufacturer bears no liability to the interpretation of these instructions Copyright 2019 Sculpt Fireplaces Collection 2 SPECIFICATIONS AXIS I1000IB Single Sided Solid steel firebox with firebricks Up to 15 30 Squares 14 6kW 1 2g kg 66 Secure Swing door opening system 4 6m 200mm 250mm 300mm Recommended for well insulated homes 10 year firebrick 5 year firebox warranty 180kg Wid...

Страница 4: ...losure must be made of a non combustible material to a height of 300mm above the appliance fascia and must extend to 100mm either side of the appliance fascia The internal wall studs of the appliance must also be made of a non combustible material IMPORTANT MANTEL SHELF Mantel shelf and mantel upright clearance was not tested and should be installed as per clause 3 4 1 3 b of AS NZS 2918 2018 A mi...

Страница 5: ...rotector should extend 550mm in front of each fuel loading door and be placed centrally in the 1300mm width The appliance is required to be installed on 40mm high spacers inside the zero clearance box between the appliance and the base of the zero clearance box PLEASE NOTE A minimum 50mm air gap must be maintained around the outer triple skin flue skin in the ceiling of the enclosure 100MM non com...

Страница 6: ...listed in this manual are recommendation only It is strongly recommended that the licensed trade professional who is performing the installation of this appliance completely read and comprehend all instructions in this manual prior to proceeding Sculpt Fireplaces Axis reserves the right to change these specifications without prior notice PLEASE READ PRIOR TO INSTALL ACCEPTABLE VARIANCE ALLOWANCE D...

Страница 7: ...2 If a floor protector hearth is to be used position now refer to clearances pg 7 8 for a guide on the appropriate positioning to accompany clearances and the floor protector hearth Step 3 Position the appliance refer to clearances pg 7 8 for minimum requirements Step 4 Prior to proceeding ensure both the zero clearance firebox and hearth are fixed in position Step 5 Refer to Flue System Installat...

Страница 8: ...arious functioning components of the appliance Insist on the wood quality on the need to light the fire correctly and have correct combustion in order to avoid all problems related to smoke emission in the room or blackened glass These installation instructions are an integral part of the appliance and should be kept indefinitely IF THE FIREPLACE IS SOLD THE MANUAL MUST ACCOMPANY THE UNIT commissi...

Страница 9: ...ombustables 500mm NON COMBUSTIBLE STUD NON COMBUSTIBLE 42mm 100mm air gap 550mm min 4600mm from the hearth to the top of the flue 500mm NON COMBUSTIBLE 5 INSTALL GUIDE single sided AXIS I1000 bench NON COMBUSTIBLE BASE HEARTH roof cavity 50MM AIR GAP TO TRIPLE SKIN FLUE triple skin flue braces to support flue roof flashing WINDRIM cowl VENTED cover cone TRIPLE SKIN FLUE roof line interior roof Thi...

Страница 10: ...3 Cut the ceiling penetration as required perform the same at the roof penetration Step 4 Frame the penetration with roofing material or timber as required Refer to minimum requirement for roof penetration AS NZS 2918 2018 Step 5 Flash the outer casing to the roof material with the appropriate approved flashing Step 6 If using an outer inner casing combination now install the inner casing ensuring...

Страница 11: ...he paint will polymerise after several fires Do not scrub or clean the fireplace with any rough surface such as a sponge In the case of accidental scratches make several fires until the paint is cured at which time you can delicately clean the outside of the appliance with a hot sponge Do not scratch or rub the fireplace while it is lit It is recommended contact with the fireplace should be kept t...

Страница 12: ...s or on the premises which share the same ventilation shaft may not function properly Please ensure the air grate is never blocked During installation please allow for access to have the fireplace and the connecting shaft cleaned If required install cut off and stifling devices RECOMMENDED FUEL This fireplace is designed for only wood fuel Any fuel other than wood is strictly forbidden As a genera...

Страница 13: ...he wood stove CLEANING THE GLASS The window of the fireplace requires regular cleaning with specific products intended for this use The use of moist hard wood with a moisture content above 15 causes excessive creosote build up on the glass Once again we recommend only burning very dry hard wood We recommend waiting for the glass to cool before cleaning it The use of products that are too aggressiv...

Страница 14: ...rt and where necessary cover glowing wood with sand Try to remove fuel from the hearth Do NOT use water to put out the fire as it may cause permanent damage Troubleshooting and course of action to put out the fireplace in the event of an emergency chimney fires continued Suggested course of action in case of chimney fires 1 Put out the fire by carefully removing the glowing logs and fully close th...

Страница 15: ...or re installation of a replacement heater is not covered 9 All warranties are void if the unit is outside and exposed to the elements PERFORMANCE The performance of our fireplaces are given as an indication and comparison after testing under optimum conditions These values reported under standard conditions may be subject to variations if the installation and conditions of use are not equivalent ...

Страница 16: ...ith a dynamic collection of designer fires Sculpt fireplace collection has strategically gathered not only award winning fireplace designs but also fireplaces that have been manufactured with high quality materials and the best raw steel that is built to last Our wood fire manufacturers integrate innovation technology environmental impact operational expertise and quality whilst holding design at ...

Страница 17: ...32 1300 851 304 info sculptfireplaces com au PO Box 1232 Mornington VIC 3931 Edition 04 07 19 ...

Отзывы: