9 Packet-Radio
130
9.8.24
MYcall
Default setting: SCSPTC
Parameter: CALL Callsign of the PTC.
Callsign for the Packet mode.
For each channel an own callsign can be defined temporarily. After a disconnect the
callsign will always be taken from channel 0 again.
After switching on the PTC-IIIusb the firmware checks if a valid callsign is written in the
PACTOR-MYCALL. In this case (i.e. no *SCSPTC* defined as PACTOR-MYCALL),
the PTC-IIIusb copies the PACTOR-MYCALL to all PR channels which are still having
SCSPTC as MYCALL, and overwrite the SCSPTC with the valid mycall. If the
MYcall
command is executed on the PACTOR side with a valid callsign as an argument, the
PTC-IIIusb also checks all PR channels for SCSPTC, and if necessary the new defined
PACTOR-MYCALL is taken over to the PR channels replacing the SCSPTC setting.
9.8.25
MYMail
Default setting: MYCALL-8
Parameter: CALL Callsign of the PR mailbox.
Identical to the
MYcall
command in the
pac:-
menu, however sets the
Mycall
of the
PTC-IIIusb PR-mailbox (BBS-MYCALL). The BBS call is set automatically to
MYCALL-8, either at the first start (when the
Flash-Call
in the BIOS has been defined),
or when ones own PACTOR-MYCALL has been set. If, for example, DL1ZAM is given
as the first PACTOR-MYCALL then the PR-mailbox can be connected with the call
DL1ZAM-8.
9.8.26
PACLen
Default setting: 255
Parameter: X
1… 255, transmit packet length
Sets the maximum PR transmit packet length, when the PTC is in Terminal mode. (In
hostmode is the
PAClen
value not used, as the hostmode program itself defines the
packet length). Packet lengths smaller than 255 are only useful if the link to the distant
station has a lot of errors. The PTC-IIIusb sends in terminal-mode a packet immediately if
a <CR> is received, which is the usual
sendpack-character
.
9.8.27
PErsist
Default setting: 64
Parameter: X 0... 255, persistence.
The persistence value sets the probability that a packet is transmitted, after the radio
channel is acknowledged as free.