6 Commands
91
Unfortunately, within the ranks of PTC clones, there is equipment that cannot convert the
umlaut (multimode controllers from the USA). In order to remain compatible with these
systems, the PTC allows the umlaut coding table to be turned off.
6.100
Unproto
Default setting: 1*2
Parameter: 1...
10,
30…41
Transmission mode for Unproto operation.
*1… 5 Number of packet repetitions.
This command allows the transmission of broadcasts (CQ calls etc). in PACTOR without
acknowledgment from the receiving station(s). An optional parameter sets the baud rate,
and the number of repetitions of packets, in the transmission. This parameter can be set
according to prevailing conditions.
Set the number of packet repetitions to 3.
cmd:
U
*3 <Return>
Now, with the following command a 200 baud transmission can be started.
cmd:
U
2 <Return>
Unproto possibilities for PACTOR-I:
Parameter Speedlevel
Packet
definition
1:
100 Bd FSK
(standard method for Level I CQ calls)
2:
200 Bd FSK
Unproto possibilities for PACTOR-II:
Parameter Speedlevel
Packet
definition
3:
100 Bd DPSK (short cycle) (standard method for
Level II only
calls)
4:
200 Bd DPSK (short cycle)
5:
400 Bd DPSK (short cycle)
6:
800 Bd DPSK (short cycle)
7:
100 Bd DPSK (long cycle)
8:
200 Bd DPSK (long cycle)
9:
400 Bd DPSK (long cycle)
10:
800 Bd DPSK (long cycle)
Unproto possibilities for PACTOR-3:
Parameter Speedlevel
Packet
definition
30: 1
short
cycle
31: 2
short
cycle
32: 3
short
cycle
33: 4
short
cycle
34: 5
short
cycle
35: 6
short
cycle
36: 1
long
cycle
37: 2
long
cycle