9 Packet-Radio
128
3 - Additionally SABM- and DISC-Frames.
4 - Additionally UA- or DM-Frames
5 - Additionally RNR, RJ and FRMR
6 - Additionally Poll/Final Bit, PID and serial numbers
9.8.19
MFIlter
Default setting: 10
Parameter: X 1... 128, max. 4 ASCII characters.
This command removes the given characters from the data stream (maximum 4
arguments). The arguments must be given in decimal or hexadecimal (prefixed with a $
character) ASCII values.
Only
works in PR-terminal-mode, and can only be accessed in that mode. (Does
not
operate in hostmode!)
Filters received and transmit characters. The default value is 10, i.e. Linefeed. This has
the effect that <CR>/<LF> in PR-Terminal-mode no longer causes incompatibility with
DieBox
mailbox systems.
If the character is set to ASCII 128, then a special filter is activated, which filters out all
CONTROL characters (range 0-31) except <CR>, <LF> and <TAB>.
Set filter for <LF> and <BELL>
pac:
MF
10 <Return>.
9.8.20
Monitor
Default setting: 0
Parameter: X 0... 6, frame type.
Switch monitor on and off.
Values greater than 0 switch the monitor on, and values greater than 1 set which frame
types will be monitored.
0 - Monitor switched off.
1 - Only UI-Frames
2 - Additionally I-Frames
3 - Additionally SABM- and DISC-Frames.
4 - Additionally UA- or DM-Frames
5 - Additionally RNR, RJ and FRMR
6 - Additionally Poll/Final Bit, PID and serial numbers
9.8.21
MStamp
Default setting: OFF
Parameter: OFF Time
stamp
off.
ON
Time
stamp
on.