SCS 724 Plus Скачать руководство пользователя страница 6

TB-9098

 Page 6 of 7

© 2020 DESCO INDUSTRIES INC

Employee Owned

SCS 

- 926 JR Industrial Drive, Sanford, NC 27332

East: (919) 718-0000 | West: (909) 627-9634 • Website: 

StaticControl.com

Alarm Types

LED(s)

Behavior

Condition

Mat 

Solid red

Worksurface not 

grounded

Operator 1 or 2 Blinking yellow Operator below low 

limit threshold

Operator 1 or 2 Solid red

Operator above high 

limit threshold

Operator 1 or 2 Blinking red

Operator body 

voltage

Operator 1 & 2 Blinking red

Operator remote 

disconnected

Operation

Using the Monitor

1.  Fit the wristband snugly onto the wrist. 
2.  Snap the wrist cord to the wristband. 
3.  Plug the wrist cord into one of the operator jacks 

on the Dual Operator Remote. The corresponding 

operator LED will illuminate solid green on the 724 

Plus Workstation Monitor. This indicates that the 

operator is properly grounded. 

4.  If this does not happen, examine the wrist cord for 

continuity or damage and the wristband to ensure 

that it fits securely. If you have dry skin, apply an 

approved dissipative hand lotion such as 

Menda 

Reztore® ESD Hand Lotion

.

Figure 9. Using the 724 Plus Workstation Monitor when 

mounted underneath a surface

Figure 10. Using the 724 Plus Workstation Monitor when 

mounted on top of a surface

Содержание 724 Plus

Страница 1: ...rds shall be established and maintained to provide evidence of conformity to the technical requirements Per ANSI ESD S1 1 Annex A 3 Daily wrist strap system testing may be omitted if constant monitori...

Страница 2: ...wer Jack Connect the included 12 VDC power adapter here E Set Switch Toggles the monitor s settings for the audible alarm mat monitor circuit and operator high test limit Feature Procedure Enable Disa...

Страница 3: ...or will alarm should the operator remote cable disconnect from this connector Workstation 2 Operator Remote Figure 4 Workstation 2 Operator Remote features and components A FRONT BACK C B D A Power LE...

Страница 4: ...1 8 Insert the tinned termination of the ground cord into the ground terminal located on the back of the 724 Plus Workstation Monitor Use a small screwdriver to secure the wire to the terminal block...

Страница 5: ...nitor from power 2 Determine the mounting location of the Workstation 2 Operator Remote Its jack should be accessible to the second operator Locate it within reach of the included operator remote cabl...

Страница 6: ...tor 1 Fit the wristband snugly onto the wrist 2 Snap the wrist cord to the wristband 3 Plug the wrist cord into one of the operator jacks on the Dual Operator Remote The corresponding operator LED wil...

Страница 7: ...240VAC 50 60 Hz Output 12 VDC 1 5 A Output Plug Polarization Center Positive Output Plug 5 5 mm O D x 2 1 mm I D x 9 5 mm L Operator Wrist Strap Dual Wire Amount Monitored 2 Resistance Limit 1 5 mego...