TB-9098
Page 4 of 7
© 2020 DESCO INDUSTRIES INC
Employee Owned
SCS
- 926 JR Industrial Drive, Sanford, NC 27332
East: (919) 718-0000 | West: (909) 627-9634 • Website:
Installation
724 Plus Workstation Monitor and Dual
Operator Remote
5. Route the operator remote cable from the back
of the 724 Plus Workstation Monitor to the Dual
Operator Remote. Connect the cable to the back of
the Dual Operator Remote.
6. Insert the tinned termination of the mat monitor cord
into the mat terminal located on the back of the 724
Plus Workstation Monitor. Use a small screwdriver
to secure the wire to the terminal block.
7. Route the mat monitor cord from the back of the
724 Plus Workstation Monitor to the grounded
worksurface mat. Use the included countersunk
washer and flat head screw to secure the cord to
the grounded mat.
NOTE: The worksurface must be connected directly
to ground without the use of a 1 megohm resistor.
Per ANSI/ESD S6.1 Section 5.2.1 Common Point
Ground:
"All of the grounding conductors from each of the
ESD technical elements (excluding level 2 technical
elements) used within an EPA shall be terminated at
the same electrically equivalent point. The common
point ground may be a terminal strip, bus bar or any
other convenient configuration that is, within itself,
electrically continuous to no greater than 1 ohm
measured from point to point with an ohmmeter as
specified in paragraph 6.1.1."
8. Insert the tinned termination of the ground cord into
the ground terminal located on the back of the 724
Plus Workstation Monitor. Use a small screwdriver
to secure the wire to the terminal block.
9. Attach the other end of the ground cord to a ground
point. The face plate screw of a grounded AC wall
outlet may provide a convenient connection point.
10. Connect the power adapter to the power jack
located on the back of the 724 Plus Workstation
Monitor. Route the wire from the supply to a nearby
AC outlet and plug it into the outlet. Make sure the
voltage and frequency match those listed on the
power supply. The 724 Plus Workstation Monitor is
now powered.
Figure 5. Installing the 724 Plus Workstation Monitor and
Dual Operator Remote
Mat Monitor Cord
724 Plus
Workstation Monitor
Grounded Worksurface Mat
Power Adapter
Operator
Remote Cable
Monitor Ground Cord
Dual Operator Remote
Countersunk
Washer
Flat Head
Screw
1. Remove the 724 Plus Workstation Monitor and its
Dual Operator Remote from the carton.
2. Determine the mounting location of the 724 Plus
Workstation Monitor. Its display should be visible to
the operator(s). Use its enclosure's mounting tabs to
secure it underneath a shelf or ledge.
3. Determine the mounting location of the Dual
Operator Remote. Its jacks should be accessible
to operators. Locate it within reach of the included
operator remote cable. Use its enclosure's
mounting tabs to secure it underneath a table top or
equipment.
4. Connect the included operator remote cable to the
dual operator remote connector located on the back
of the 724 Plus Workstation Monitor.