background image

 

6

3.4 Enter into the TEST Mode 

 

There are 3 states in TEST Mode: preview state (preview the scene in 

the front of the camera), setting state (make customer settings), and playback 
state (view Photos or videos via 2.0” TFT display).   

(Note: SG560P0 model has no preview and playback.)   

 

3.4.1

 Preview 

 

 

 

 

       

After switching the camera to TEST Mode, it enters into the preview state.   

Press 

    to exchange between playback mode and preview mode;   

 

3.4.2

 Customer Settings 

 

Press 

MENU

 to manually customizing the camera settings which 

displayed on the screen or external TV monitor. The detailed operations will 
be described in “Advanced Operations” chapter.   

3.4.3

 Manual Capturing 

 

Press 

 

to manually capture photos or record videos. Press again 

   

to stop the manual capturing of a video.   

3.4.4

 View Images

 

or Videos 

 

There are two ways to view the captured images or videos:   
  1. LCD screen on the control   
  2. TV monitor which connect to camera with TV cable   
 Press 

 

to view images or videos, the latest image or video will be 

shown in the LCD screen on the control or TV monitor. Press 

” 

or 

 to 

view the previous or next image or video.     

 

3.4.5

 Delete Images

 

or Videos 

 

 
   

Press 

DEL

 to delete images or videos .Note the 

DEL 

button just works in 

Playback state. So if it’s in Preview state, you should press 

  to enter into 

Playback state.   

   

 

3.5 Triggering modes 

 

There are 3 triggering modes of the camera: PIR triggering

Timer 

triggering and PIR&Timer triggering.   
 
   

 

3.5.1

 PIR Triggering   

 

 

PIR triggering is the default setting. The camera works only when motions 

get detected, while, if PIR sensitivity is set as 

PIR OFF

, the camera stops PIR 

triggering.  

 

3.5.2

 Timer triggering

 

 

 

 

The

 Timer interval 

Default setting is 

OFF

 which means the timer 

triggering is disabled. While changing the timer triggering interval to a 
non-zero value, the camera starts to work at a preset interval. User need to 
OFF the PIR triggering (choose

 PIR sensitivity

 as 

PIR OFF

) if want the 

Содержание DTC-560K

Страница 1: ...0 Infrared Digital Scouting Camera 8MP Scouting Camera DTC 560K User s Manual ...

Страница 2: ... 6 Power Off 7 4 Advanced Operations 7 4 1 Settings Menu 7 4 1 1 Set Camera Mode 7 4 1 2 Format SD Card 7 4 1 3 Set Photo Size 8 4 1 4 Set Video Size 8 4 1 5 Set Date and Time 8 4 1 6 Set Photo Burst 9 4 1 7 Set Video Length 9 4 1 8 Set PIR Sensitivity 9 4 1 9 Set PIR Triggering Interval 10 4 1 10 Set Timer Triggering Interval 10 4 1 11 Set Timer Switch 10 4 1 12 Set Time Stamp 11 4 1 13 Reset to ...

Страница 3: ...deos according to previously programmed settings The device is designed for outdoor use and is resistant against water and snow Furthermore the camera can be used as a portable digital camera Pictures or videos can be taken manually by pressing on the operation panel 1 2 Application This camera can be used as automatic surveillance device for guarding and recording unexpected intrusion to homes sh...

Страница 4: ...3 Figure 1 Front view Figure 2 Operation interface Figure 3 Bottom view ...

Страница 5: ...hange between playback mode and preview mode DEL to delete an image to capture a photo or record a video manually 1 3 3 Shooting Information Display 1 4 Saving Images or Videos The Camera uses a SD card to save images in jpg format and videos in avi format Before inserting the SD card be sure that the SD card is unlocked The camera is compatible with SD card from 8MB to 8GB ...

Страница 6: ...ensity and high performance alkaline batteries Recommended 2 Rechargeable alkaline batteries 3 Rechargeable NiMH batteries When in low battery state camera will be automatically shut down after the indication LED flashing for a while Please change the batteries in time 3 2 Insert the SD card The camera has no internal memory for saving images or videos If no SD card is inserted or SD card is locke...

Страница 7: ...een on the control 2 TV monitor which connect to camera with TV cable Press to view images or videos the latest image or video will be shown in the LCD screen on the control or TV monitor Press or to view the previous or next image or video 3 4 5 Delete Images or Videos Press DEL to delete images or videos Note the DEL button just works in Playback state So if it s in Preview state you should pres...

Страница 8: ...ew the camera settings menu press MENU in the TEST mode Power switch is at TEST position The settings menu will be shown on the LCD on the camera or the external TV monitor only when the camera is connected to a TV 4 1 1 Set Camera Mode There are two modes Camera Video Camera mode The camera takes photos when it is triggered Video mode The camera takes videos when it is triggered There are two way...

Страница 9: ...tion will be un highlighted Press MENU to return to info display 4 1 4 Set Video Size This parameter also has two values VGA 640 480 and QVGA 320 240 The default value is 640x480 VGA The following shows how to set video size as 320 240 provided that the previous option is 640 480 e Press MENU to display the setting menu f Press or to select Video Size g Press to select 320 240 h Press OK to save t...

Страница 10: ...h to 15 Seconds provided that the previous value is 1 Seconds a Press MENU to display the setting menu b Press or to select Video Length c Press to increase to 15 Seconds d Press OK to save the current setting and the option will be un highlighted Press MENU to exit 4 1 8 Set PIR Sensitivity This parameter defines the sensitivity of the PIR There are four parameters High Normal Low and PIR off The...

Страница 11: ...als regardless of weather there are motions get detected The default parameter is OFF which means the timer function is disabled When changing this parameter to a non zero value it starts to take photos at given time interval The value ranges from 10 seconds to 8 hours Press and to decreases or increases the value The following shows how to set timer interval to 1 hour provided that the previous v...

Страница 12: ...d return to info display 4 1 13 Reset to Default Settings To reset the setting to the default values the steps are as follows a Press MENU to display the setting menu b Press or to select Reset c Press OK to reset to default settings and return to info display Press MENU to cancel setting and return to info display 4 2 Default Settings and Live Monitoring Please refer to table 1 for the default se...

Страница 13: ...quality the recommended distance is 5m from the tree to the target monitoring area and recommended height from the ground is 1 5 2 meters Adjust the viewing angel properly view angle of this camera is 52 There are two ways to mount the camera using a band shaped belt bottom screw Using the belt To use the belt to fix the camera on a tree is illustrated in Fig 4 Take the belt toes to go through the...

Страница 14: ...e When the detection angle is 35 the detection range is 50ft When the detection angle is 52 the detection range is 30ft Figure 4 The PIR detection angle α is just barely larger than the field of view angle β The advantage of this design is to avoid empty pictures and get available pictures Figure 5 ...

Страница 15: ...0K has a new design of PIR and this new PIR is patented The new patented PIR s detection range can reach to 25m The figure 6 shows the compared detection zone between normal PIR and the new patented PIR Figure 6 ...

Страница 16: ...ensor Multi Zone PIR Sensitivity Adjustable High Normal Low Trigger Time 1 2s Weight 0 24 kg Operation Storage Tem 20 60 C 30 70 C Interval 1s 60 min Photo Burst 1 3 Video Length 1 60s Power Supply 8 AA recommend 4 AA urgent Stand by Current 0 3 mA 7mAh Day Power Consumption 150 mA 450mA when IR LED lighted Low Battery Alert LED Indicator Display Screen LCD display Mounting Rope Belt Python lock D...

Страница 17: ...16 AppendixⅢ Parts List Part Name Quantity Digital Camera One TV Cable One USB Cable One Belt One User Manual One ...

Отзывы: