Page 26 of 36
P/N 595289-01 Rev B 5/15
CHECK YOUR WORK!
BEFORE ASSEMBLY OF BATTERY COVER,
CHECK TO SEE ALL BATTERIES ARE FRESH,
NEW BATTERIES OF THE TYPE INDICATED
ABOVE AND THAT THEY HAVE BEEN INSTALLED
PROPERLY.
BE SURE SEALING
SURFACES ARE CLEAN
BEFORE REASSEMBLY
6. The battery cover must be installed so that it is water tight after replacement.
Clean the sealing rib around battery compartment and sealing face of the cover
by wiping with a clean damp cloth to remove any dirt or foreign matter which might
prevent a proper seal. Check cover gasket for tears or cuts. If damage is found,
remove respirator from service and tag for repair by authorized personnel.
7. To install battery cover, align the three grooves on the cover with the three tabs
on the battery compartment and tighten the cover screw.
8. To test the batteries, verify that the PAK-ALERT distress alarm is in the off condi-
tion (cylinder valve closed with no flashing green LED on the control console).
a) Press and hold the reset button on the console. A GREEN light on the console
indicates sufficient battery power and that the batteries are properly installed.
b) If the unit displays the LOW BATTERY condition or no light at all, verify that
the batteries are properly installed. If the batteries were properly installed,
remove the batteries and replace with a new set of six (6) batteries.
c) If another set of properly installed batteries will still not produce a GREEN
light on the battery test, remove the unit from service and mark for repair by
authorized personnel.
AFTER REPLACEMENT OF BATTERIES, PERFORM A REGULAR OPERATIONAL
INSPECTION BEFORE RETURNING RESPIRATOR TO SERVICE.
BATTERY REPLACEMENT CONTINUED...
CAUTION
IMPROPER BATTERY COVER INSTALLATION
CAN CAUSE BATTERIES TO OVERHEAT AND
MAY CAUSE DAMAGE TO THE PRODUCT.
ALWAYS MAKE SURE THAT THE ALIGNMENT
GROOVES ON THE BATTERY COVER ARE
ALIGNED WITH THE TABS ON THE BATTERY
COMPARTMENT DURING INSTALLATION OF
THE COVER.