When performing the REGULAR OPERATIONAL INSPECTION verify that
the Sensor Module lights are operating as described below:
OPERATION OF SENSOR MODULE LIGHTS
NOTE
THE ORANGE LIGHT IS A COMBINATION OF THE RED, GREEN, AND BLUE
LIGHTS THAT APPEARS ORANGE FROM A DISTANCE. AT CLOSE RANGE THE
INDIVIDUAL LIGHTS MAY BE VISIBLE.
ACTION...
SENSOR MODULE LIGHTS WILL…
Start up PASS (Open Cylinder) .................................................. Bright Light then Flash GREEN
Normal Operation ........................................................................ Flash GREEN
Respirator Low air (1/3 cylinder) ................................................. Flash ORANGE (alternately)
Low Battery while ON .................................................................
GREEN light stops flashing
Shut down .................................................................................. Lights OFF
Press RESET w/unit OFF (BATTERY TEST) ........................... Bright Light then:
Flash GREEN if Good/Flash RED if Low
Press MANUAL ALARM with unit OFF ..................................... Flash GREEN then Full Alarm Flash RED
Press RESET from manual alarm ............................................. Returns to Flash GREEN
PASS Pre-Alarm ........................................................................ Flash RED (alternately)
PASS Full alarm ......................................................................... Flash RED (simultaneously)
REGULAR OPERATIONAL INSPECTION CONTINUED...