FOR THE ELECTRICIAN
CONFORM TO ALL APPLICABLE CODES
The electrical power to the unit is to be wired
through the cabinet to the control box. In the
control box, connect to the terminal strip provided.
1. Remove the front, top and right side panels.
2. Remove the control box cover.
3. Route the power cord thru the cabinet to the
control box.
4. Connect wires to the terminal strip.
5. Replace all panels.
Check the nameplate (located on the back of the
cabinet) for the voltage requirements, and for the
minimum circuit ampacity. The machine requires
a solid chassis to earth ground wire.
The ice maker should be
connected to it’s own electrical
circuit so that it is individually
fused. Voltage variation must
remain within design limitations,
even under starting conditions.
All external wiring must conform to
national, state, and local electrical
codes. The use of e licensed
electrician is required to perform
the electrical installation.
ELECTRICAL POWER
SUPPLY
CONNECT ELECTRICAL
POWER TO ICE MAKER
THROUGH ELECTRICAL
INLET HOLE AND INTO
CONTROL BOX
MFE400
May 1994
Page 6