REMOVAL AND REPLACEMENT

Ice Breaker and Auger Removal

1. Remove styrofoam cap and two screws from the
side of the evaporator.

2. Pull up on cap hook located in the top of the
freezer assembly to remove the ice breaker
assembly, auger, and the top portion of the water
seal.

3. Remove the snap ring and cap, and remove the
bolt from the ice breaker and auger assembly to
separate the ice breaker assembly from the auger.
The bearings may be replace or the ice breaker
and bearings may be replaced as an assembly.

3. Apply Scotsman part number 19-0529-01 food
grade sealant to the auger shoulder before
pushing on the water seal. Place just enough
sealant onto the shoulder of the auger, so that
when the water seal is placed on the auger, the
gap between the auger shoulder and the water
seal is completely filled with the sealant.

4. Clean the inside of the evaporator at the bottom
bearing and water seal mounting area. Lubricate
the outside edge of the stationary seal with water.

5. Carefully push the stationary part of the water
seal up into the bottom of the evaporator. It must
go in straight and must not be pushed in beyond
1/4" past the bottom of the evaporator.

6. Install a new bottom bearing, push it into the

evaporator under the new
water seal. It must be pushed
in straight, but do not push it in
past 1/8" from the bottom of
the evaporator tube.

7. Mount the adapter stand to
the bottom of the evaporator.
Hand tighten the three cap
screws until the stand flange is
tight against the bottom of the
evaporator. Hand tighten the
three cap screws until the
stand flange is tight against

the bottom bearing. Then,
tighten the screws in a rotating
pattern to insure proper

alignment.

8. The

top bearing should also be
changed at this time. Be sure
to mount the top

breaker/bearing assembly onto the
auger before installing the auger into the
evaporator tube.

9. Lower the auger into the evaporator,
twist it to engage the splines of the
coupling. Secure the breaker and
bearing to the evaporator tube with the
two screws removed in step 1 of “Ice
Breaker and Auger Removal”. Test the
unit.  

Narrower

at Top

Sealant Here

Outer Race

Wider at Top

Inner Race

Water

Seal

Rubber

Metal

Water Seal Installation

Inspect the water seal in
it’s package. Do no use if
mating surfaces are
scratched or cracked.

1. Remove auger, unbolt
evaporator from adapter
stand. Drive out old
bottom bearing and water
seal from the top down.

2. Remove the old
rotating half of the water
seal from the auger and
clean the auger at the
seal mounting area.

MFE400

May 1994

Page 17

Содержание MFE400

Страница 1: ...Assembly Page 4 For the Plumber Page 5 For the Electrician Page 6 Final Check List Page 7 Start Up Page 8 Component Description Page 9 Electrical Sequence Page 10 Operation Page 11 Maintenance Cleanin...

Страница 2: ...ser Drain 3 8 O D Tube Water Cooled Condenser Inlet 3 8 O D Tube Water Cooled Electrical Inlet 2 5 8 9 5 Drain 7 16 I D Hose 2 3 5 Water Inlet 3 8 Male Flare MFE400AS 1 MFE400WS 1 MFE400WS 1 MFE400AS...

Страница 3: ...bject to change without notice Water Limitations An ice machine is a food manufacturing plant it takes in a raw material water and turns it into a food product ice The purity of the water is very impo...

Страница 4: ...base of the machine is over the open hole in the bin top Ice Chute Installation After the MFE400 has been installed on the ice storage bin the ice chute needs to be installed 1 With the top panel off...

Страница 5: ...ect to for a drain This drain is a gravity drain and a minimum of 1 4 per foot fall is needed for horizontal portions of the drain line The ideal drain receptacle is a trapped and vented floor drain U...

Страница 6: ...ack of the cabinet for the voltage requirements and for the minimum circuit ampacity The machine requires a solid chassis to earth ground wire The ice maker should be connected to it s own electrical...

Страница 7: ...machine 3 Have all the plumbing connections been made and checked for leaks 4 Has the machine and bin been leveled 5 Is there a minimum of 6 clearance around the machine for proper service and air ci...

Страница 8: ...to drop ice into the storage bin 7 Let the unit operate for 15 30 minutes checking for water leaks or excessive noise from vibrating components 8 Block off the ice discharge tube and check if the bin...

Страница 9: ...pressure become too high usually as a result of not enough water through the water cooled condenser It is a manual reset On Off switch This toggle switch shuts off the machine It is not a complete dis...

Страница 10: ...r through the auger delay pressure control until the compressor starts and the low side pressure drops The next control the power is connected to is the Low Water Pressure Control This switch is desig...

Страница 11: ...of the evaporator Reservoir overflows routed to the drain Water cooled models have a separate water circuit for the cooling water it enters the fitting at the rear goes to the water regulating valve...

Страница 12: ...t more refrigerant and colder evaporators get less At the evaporator the refrigerant enters an area of relatively low pressure where it can easily boil off or evaporate As it evaporates it absorbs hea...

Страница 13: ...ru steps 13 18 to sanitize the ice machine water system 13 Mix two gallons of sanitizer solution Use an approved sanitizer A possible sanitizing solution may be obtained by mixing 1 ounce of household...

Страница 14: ...g 1 Remove styrofoam cap and two screws from the side of the evaporator 2 Remove the snap ring and cap and remove the bolt from the ice breaker and auger assembly to separate the ice breaker assembly...

Страница 15: ...fan motor or water supply Auger drive motor open Check auger drive motor Centrifugal switch open Check centrifugal switch Auger delay switch open Check replace auger delay No ice auger motor turning A...

Страница 16: ...ger drive Compressor too loud Replace compressor Gear noise Check gearmotor for oil leak Water leaks from cabinet Evaporator water seal worn or cracked Replace seal and bearings Tubing to evaporator l...

Страница 17: ...stall a new bottom bearing push it into the evaporator under the new water seal It must be pushed in straight but do not push it in past 1 8 from the bottom of the evaporator tube 7 Mount the adapter...

Страница 18: ...ads from their connections 6 Raise the evaporator assembly up enough that the output shaft clears the freezer adapter 7 Remove the gearmotor assembly from the ice machine Gearcase Service After remova...

Страница 19: ...MOTOR COVER FAN WINDING ROTOR FIRST GEAR AND PINION SHAFT SEALS OUTPUT SHAFT KEY Gearmotor Service MFE400 May 1994 Page 19...

Страница 20: ...ut holding reservoir to its mounting bracket 7 Remove reservoir from the machine 8 Reverse to reassemble Float Valve 1 Shut off the water supply 2 Remove the top panel 3 Remove the reservoir cover 4 R...

Страница 21: ...es must be in the closed position before the hose caps are removed Do not remove the hose caps before checking the position of the valve Use a 3 16 allen wrench to open and close the valve Recovery an...

Отзывы: