SECTION VI
SERVICE DIAGNOSIS
The Service Diagnosis Section is for use in aiding
the servicemen in diagnosing a particular problem
for pin-pointing the area in which the problems
lines, thus an ever available reference for proper
corrective action.
The following chart lists corrective actions for the
causes of known symptoms of certain problems
that can occur in the ice makingrefrigerarion
system.
SYMPTON
POSSYBLE CAUSE
CORRECTION
Red Light glows-
Intermittent water supply
Water shut-off valve closed.
Lo-water pressure.
or too low water pressure.
Check and clean water strainer.
The unit does not make ice.
Fiber key in gear reducer
Remove Gear box
bore broken.
and change fiber key.
V-belt loose or broken.
Check. Repair or replace.
The compressor runs but no
Gear in gear box stripped.
Check and replace.
ice is made.
Pulley loose on motor shaft.
Repair.
Water not entering reservoir.
Check and clean. Water float
valve to be cleaned.
Red Light glows-
Hi-pressure control cut-off
Check cooling water at
Hi-pressure excessive.
unit operation.
condenser. Condenser tube
clogged-up. Water regulating
valve to be re-adjusted.
Fan motor out of operations.
Green Light is
Blown fuse.
Replace fuse and check for
off. Unit will not run.
cause of blow fuse.
Loose electrical connection.
Check wiring.
Switch in OFF position.
Turn switch to ON.
Inoperative master switch.
Replace switch.
Spout switch cut-out.
Check ice chute arrangement.
Contactor coil-open winding.
Replace contactor.
1. ICE MAKING - REFRIGERATION SYSTEM
Page 33
Содержание MAR 106
Страница 36: ...Page 36 MAR 56 76 106 126 AS and WS WIRING DIAGRAM...
Страница 37: ...Page 37...
Страница 38: ...Page 38...
Страница 39: ...MAR 206 306 AS and WS WIRING DIAGRAM FIG 1 Page 39...
Страница 40: ...MAR 206 306 AS and WS WIRING DIAGRAM FIG 2 Page 40...
Страница 41: ...Page 41...
Страница 42: ...Page 42...