20. Plug IN the ice maker and let the unit in
operation for about 10 minutes.
21. Disconnect again unit from power.
22. Repeat again from #5 to #9 thus to dump
reservoir from chemical solution and later
rinse all parts by fresh water.
23. Reinstall all removed part from #9 to #5.
24. Prepare as per #12 using SCOTSMAN
sanitizer rather then cleaner. Possible
sanitizing solution could be by mixing 1,5 cl
(5 oz) of sanitizer with 5 lt (1 gallon)
NEVER MIX CLEANING WITH SANITIZING
SOLUTION
25. Pour sanitizing solution in the water reservoir.
26. Plug IN again the unit and let the sanitizing
solution re-circulating for about 5 minutes.
27. Repeat #5 to #8.
28. Lift the water sump up for a while in order to
dump sanitizing solution stored in the same
then relocate the same.
29. Reinstall water pump and connect water inlet
hose.
30. Open water inlet valve previously closed at #4.
31. Ice produced during the first 5 minutes must
be thrown away in order to avoid any possible
chemical contamination.
CAUTION - NEVER use ice produced from
any chemical solution. Be sure none falls
into storage bin.
3B. CLEANING INSTRUCTION
(MAR 206-306)
1. Disconnect power front the unit.
2. Remove screws and top panel
3. Remove evaporator cover panel
12. Prepare a solution in a bucket by mixing
1/2 liter of SCOTSMAN CLEANER with 5
liters of warm (40-50
°
C) water.
WARNING: When using any chemical,
wear hands protection (gloves).
SCOTSMAN Ice Machines Cleaner
contains phosphoric and Hydroxiacetic
acid. These compound are corrosive and
may cause burns if swallowed. DO NOT
induce vomiting. Give large amount of
water or milk. Call Physician immediately.
In case of external contact, flush with
fresh water. KEEP OUT OF THE REACH O
CHILDREN.
13. Dip the water reservoir removed at #7 into
the cleaning solution and clean it by sponge
and/or suitable brush.
14. Once reservoir is duly cleaned, dump float
valve in the solution and remove any kind of
scale or mineral deposit then rinse the same
by fresh water.
15. Place again float valve into its bracket
16. Reinstall water sump with float valve.
17. Reinstall water pump removed at #6.
18. Reconnect water inlet hose removed at #5.
19. Slowly pour the solution mixed at #12 in the
water reservoir till to 2 cm (7,87") below top
edge.
Page 31
Содержание MAR 106
Страница 36: ...Page 36 MAR 56 76 106 126 AS and WS WIRING DIAGRAM...
Страница 37: ...Page 37...
Страница 38: ...Page 38...
Страница 39: ...MAR 206 306 AS and WS WIRING DIAGRAM FIG 1 Page 39...
Страница 40: ...MAR 206 306 AS and WS WIRING DIAGRAM FIG 2 Page 40...
Страница 41: ...Page 41...