SYMPTON
POSSYBLE CAUSE
CORRECTION
Excessive noise.
Misaligned V-belt.
Aligne V-belt.
Gear reducer loose on frame.
Tighten.
Drive motor end-play or worm
Repair or replace.
bearings.
Motor compressor not
Loosen hold-down bolts.
floating on rubber cushions.
Water level in evaporator
Set water level as shown
drum basin too low.
on page 27.
Excessive vibration.
Ice formation underneath
Remove blade amd melt-up
blade-frictioning against
ice formation.
rotating drum.
Adjust water level as shown
on page 27.
Compressor cycles
Water regulating valve too close.
Open water valve.
AEV valve closed.
Adjust.
Non-condensable gases in sustem.
Purge-off.
Making wet ice
Surrounging air temperature
Correct or move unit to cooled
above 40
°
C (100
°
F)
location.
Under-or-over-charge of refrigerant.
Re-charge with proper amount.
Closed AEV.
Adjust valve for correct refrigerant
flow.
Faulty compressor valve plate.
Repair or replace.
Low ice production.
Loss of refrigerant, under
Check and recharge with
or overcharge of refrigerant.
proper amount of refrigerant.
Plugged condenser water tubes.
Clean condensor.
Low water level in the reservoir.
Check float valve operation.
Overcharge of oil in system.
Check at oil sight glass.
Lower to 1/2 sight glass.
Light glows-
Evaporator - drum speed very
Gear Reducer shaft's fiber key
Evaporator - drum doesn't turn
low - 1/4 rotation in more then 40"
breakage.
(ice maker OFF).
V belt slipping
Effect hall sensor failure.
Effect hall magnetic pins
demagnetized.
Light glows-
Wrong power voltage cable
Interchange phases plug IN.
Wrong 3 phases monitoring
wiring.
relay cut out.
Page 34
Содержание MAR 106
Страница 36: ...Page 36 MAR 56 76 106 126 AS and WS WIRING DIAGRAM...
Страница 37: ...Page 37...
Страница 38: ...Page 38...
Страница 39: ...MAR 206 306 AS and WS WIRING DIAGRAM FIG 1 Page 39...
Страница 40: ...MAR 206 306 AS and WS WIRING DIAGRAM FIG 2 Page 40...
Страница 41: ...Page 41...
Страница 42: ...Page 42...