Start Up
After having correctly installed the ice maker and
completed the plumbing and electrical
connections, perform the following “Start-up”
procedure.
A. Remove the condenser air filter then remove the
front panel, Locate the cleaning switch on the
control box.
B. Switch the cleaning switch to the cleaning
position. This will close the electrical circuit to the
water inlet valve and to the hot gas valve
C. Switch the power ON and push the green button
switch. Unit will start up in charging cycle mode.
During this cycle the components energized are:
·
Water Inlet Solenoid Valve
·
Hot Gas Solenoid Valve
·
Water Pump
·
Fan Motor
D. Operate the unit in the water charging cycle for
about three/four minutes till water flows out from
the drain hose, then move the cleaning switch to
the operation position.
NOTE. During the charging cycle, the water inlet
solenoid valve is energized. The water flows
through the valve to the back side of the
evaporator platen and then down to fill up the ice
machine sump for the next freezing cycle.
CU0515
April 2007
Page 6
Air Filter Removal
Front View With Front Panel Removed
Cleaning
Switch
Green Power
Switch