Service Diagnosis
• Makes ice, but ice is cloudy or not completely
formed
– Spray jets restricted, clean machine
– Lack of rinse water due to hot room temperature
• Adjust harvest time longer to drain more water
• Makes ice but they are blocks or shells
– Ice bridge wrong size
– Evaporator thermistor out of calibration
– Evaporator thermistor failure
– Poor contact of thermistor probe to suction line
Содержание CU0415
Страница 1: ...Technical Training CU0415 CU0715 CU0920 Essential Ice ...
Страница 2: ...Presentation Topics Introduction Installation Operation Cleaning Diagnostics Service ...
Страница 5: ...Evaporator Nickel Plated Copper Mounted inverted above spray platform ...
Страница 11: ......
Страница 13: ...Installation Water and Drain all models Drain is FPT Must be vented ...
Страница 14: ...Installation Water Connection 115 60 inch OD plastic tubing routed out the back No fittings are supplied ...
Страница 21: ...Controller Information Freeze Mode Light Timer Light Ice bridge and harvest time setting indicators ...
Страница 22: ...K1 K1 K1 K2 K2 ...
Страница 25: ...Ice Bridge 3 16 ...
Страница 26: ...Adjustments Increase or Decrease Bridge Thickness Increase or Decrease Harvest Time ...
Страница 33: ...Cleaning and Maintenance ...
Страница 35: ...Reservoir Drain Plug ...
Страница 37: ...Spray Platform Inlet engages clip in reservoir pull forward to remove ...
Страница 38: ...Spray Platform Assembly ...
Страница 40: ...Maintenance and Cleaning Clean air cooled condenser Vacuum and brush dirt from fins ...
Страница 59: ...Cabinet Removal Lift bin with reservoir off the deck Remove deck cover Deck Cover ...
Страница 60: ...Cabinet Removed ...
Страница 61: ...Questions ...