Water System Cleaning
• Remove front panel and switch the Master Switch
to OFF, wait 1 minute then switch it to ON.
– Manual harvest, releases any ice on the evaporator
• Switch unit off, discard all ice.
• Drain reservoir by pulling the drain plug and then
putting it back.
• Mix 5 oz of Scotsman Clear 1 scale remover and
2 ½ quarts of warm water.
Содержание CU0415
Страница 1: ...Technical Training CU0415 CU0715 CU0920 Essential Ice ...
Страница 2: ...Presentation Topics Introduction Installation Operation Cleaning Diagnostics Service ...
Страница 5: ...Evaporator Nickel Plated Copper Mounted inverted above spray platform ...
Страница 11: ......
Страница 13: ...Installation Water and Drain all models Drain is FPT Must be vented ...
Страница 14: ...Installation Water Connection 115 60 inch OD plastic tubing routed out the back No fittings are supplied ...
Страница 21: ...Controller Information Freeze Mode Light Timer Light Ice bridge and harvest time setting indicators ...
Страница 22: ...K1 K1 K1 K2 K2 ...
Страница 25: ...Ice Bridge 3 16 ...
Страница 26: ...Adjustments Increase or Decrease Bridge Thickness Increase or Decrease Harvest Time ...
Страница 33: ...Cleaning and Maintenance ...
Страница 35: ...Reservoir Drain Plug ...
Страница 37: ...Spray Platform Inlet engages clip in reservoir pull forward to remove ...
Страница 38: ...Spray Platform Assembly ...
Страница 40: ...Maintenance and Cleaning Clean air cooled condenser Vacuum and brush dirt from fins ...
Страница 59: ...Cabinet Removal Lift bin with reservoir off the deck Remove deck cover Deck Cover ...
Страница 60: ...Cabinet Removed ...
Страница 61: ...Questions ...