CURTAIN
INLET WATER
VALVE
Spray Platform
1. Open ice bin door.
2. Pull out on the left side and remove curtain
assembly.
3. Lift the spray platform up and pull out to get to
the water hose at the base of the platform.
4. Pull hose off of connection to spray platform,
and pull platform from ice maker.
5. To replace, reverse the removal procedures.
Water Inlet Valve
1. Unplug the ice maker to disconnect electrical
power.
2. Shut off water supply to ice maker.
3. Remove the lower back panel, pull out to
expose inlet water valve.
4. Disconnect electrical wires from inlet water
valve.
5. Disconnect water lines to and from water
valve.
6. Remove valve from ice maker.
7. Reverse removal procedure to replace.
Water Pump
1. Disconnect ice maker from electrical power.
2. Remove top panel.
3. Open ice bin door pull up through top and
remove.
4. Remove curtain by pulling forward and out on
the left end.
5. Remove 2 screws holding pump bracket to
right side panel.
6. Disconnect 2 electrical leads and 1 ground
wire from pump.
7. Pull out spray platform, lift pump and
disconnect hose.
8. Pull water pump up and out of ice maker.
9. Dismount water pump from cover assembly
(retaining the brackets), and remount the
replacement pump in its place.
10. Reverse the balance of the steps to
reassemble.
REMOVAL AND REPLACEMENT
Electrical Shock Hazard.
Disconnect electrical
power before beginning.
CS60
January 1995
Page 17