Cleaning, Sanitation and Maintenance
This ice system requires three types of
maintenance:
•
Remove the build up of mineral scale from the ice machine’s water system and sensors.
•
Sanitize the ice machine’s water system and the ice storage bin.
•
Clean the remote condenser.
It is the User’s responsibility to keep the ice machine and ice storage bin in a sanitary condition. Without
human intervention, sanitation will not be maintained. Ice machines also require occasional cleaning of
their water systems with a specifically designed chemical. This chemical dissolves mineral build up that
forms during the ice making process.
Sanitize the ice storage bin as frequently as local health codes require, and every time the ice machine
is cleaned and sanitized.
The ice machine’s water system should be cleaned and sanitized a minimum of twice per year.
1.
Remove front panel.
2.
Push and release the blue Harvest button.
Machine will go thru a manual harvest of 3
minutes then shut off.
3.
Remove all ice from the bin.
4.
Push and release the yellow Clean button.
5.
Wait until the Purge Valve light goes out, then
pour 24 ounces of Scotsman Clear 1 Scale
remover into the water reservoir.
6.
Operate the machine for at least 10 minutes.
7.
Push and release the yellow Clean button
again.
8.
Operate the machine for at least 20 minutes,
then push the red Off button.
9.
Check for scale, repeat steps 3 thru 7 if scale
is still evident.
10. Disconnect pump hoses from water
distributors.
11. Depress snaps and pull water distributors
forward and out of the machine. Remove
covers and inspect for scale. Remove any
remaining scale. Set aside.
12. Remove evaporator covers, set aside.
13. Remove right side panel and liner, set aside.
14. Remove all three curtains. Set aside.
15. Twist counterclockwise and lift water pumps up
and tip to one side.
16. Remove front water reservoir cover plate, set
aside.
17. Remove sump cover and water level sensor,
set sump cover aside.
18. Pull water reservoir forward; tip up and out of
the machine.
19. Mix a locally approved sanitizer solution. If
approved, mix one ounce of liquid household
bleach to two gallons of lukewarm (95-100
degrees F.) water.
20. Thoroughly wash the water reservoir cover
plate, sump cover, water distributors, distributor
covers, evaporator covers, right side panel
October 2010
Page 20
C2648
Remote Condenser Models - User Manual
Ice machine cleaner contains
acids. Acids can cause burns.
If concentrated cleaner comes
in contact with skin, purge with
water. If swallowed, do NOT
induce vomiting. Give large
amounts of water or milk. Call
Physician immediately. Keep
out of the reach of children.