Shut down on maximum
harvest time (continued)
Curtain switch does not open
when curtain does
Check switch with ohmmeter
Machine in very cold ambient
Move machine to a warmer
location
Hot gas valve does not open
Check hot gas valve, check
controller using test mode
Harvest assist probe out of
position – ejector pin not retracted
Check harvest assist mechanism
– spring should retract pin
Damaged evaporator
Check evaporator surface
Shut down on minimum
freeze time
Grounded ice thickness sensor or
bridge too thin
Check sensor for dirt and position.
Clean and adjust gap to
evaporator surface using 7/32”
drill bit as a gauge
Improper water flow
Check water distributor cover, be
sure it is sealed tightly
Check/clean spillway surface to
improve water flow
November 2010
Page 21
C2648 Service Manual
Problem
Likely Cause
Probable Solution
Diagnostics - Remote Air Cooled