Performance Information
November 2010
Page 37
C2648 Service Manual
Condenser Intake Air Temp., Degrees F
-20
70
80
90
120
Cycle Time
(minutes)
Water Temp
50
70
80
90
9-11
10-12
11-13
12-14
10-12
11-13
12-14
13-15
11-13
12-14
13-15
14-16
12-14
13-15
14-16
15-17
16-18
17-19
18-20
19-21
Suction Pressure
(PSIG)
End of Freeze
Harvest
28-30
73-75
26-28
78-80
27-29
78-80
27-30
78-80
34-36
86-89
Discharge Pressure
(PSIG)
End of Freeze
Harvest
205-210
150-155
230-235
170-175
238-243
178-183
245-250
195-190
365-370
245-255
Ice per cycle, 21 lb.
Compressor Amps:
•
Freeze - 13.2 to 12.9, declining to 9.6 at the end of the freeze cycle. 11.6 to 11.9 at five minutes.
•
Harvest - 12.7 to 11.8