IRD-2600 / IRD-2800
Integrated Receiver Decoders
P/N 2349-72784-00
Page 3-27
Table 3-9:
System Configuration Menu Options
OPTION
DESCRIPTION
Control Port Baud Rate
Control Port Rate Select
Selects the Baud rate of the RS-232/RS-488 Control Port.
Available options:
9600 Baud, 19200 Baud, 38400 Baud, 57600 Baud, 115200 Baud
Control Port Address
Control Port Address Set-Up
Sets the address of the RS-232/RS-488 Control Port.
Address is given in two digits decimal number.
Range: 128-255(Dec).
Data1 HSD Output
Format
Data1 Output Format Select
This parameter sets the Data1 / HSD output format. Available on the
DATA Output connector.
Available options:
RS-422 (MSB to LSB):
Transmits bytes from MSB to LSB.
RS-422 (LSB to MSB):
Transmits bytes from LSB to MSB.
Data2-LSD Output
Format
Data2 Output Format Select
This parameter sets the Data2 / LSD output format.
Available options:
RS-232: Transmits on PS-232 port, on the DATA Output Connector.
RS-422 (MSB to LSB):
Transmits bytes from MSB to LSB on RS-422 port.
RS-422 (LSB to MSB):
Transmits bytes from LSB to MSB on RS-422 port.
NOTE
(*):
The RS-422 level output is available on an extended DATA Output
Connector (Optional).
Data1-HSD Output Rate
Data1 Output Rate Set-Up
This parameter sets the Data1 / HSD output rate.
Available rates:
10 K b/s
through
20 M b/s.
Data2-LSD Output Rate
Data2 Output Rate Set-Up
This parameter sets the Data2 / LSD output rate.
Available rates:
1200 Baud
through
115200 Baud.
Default Data Port
Default Data Port Definition
Determines the default data port when the data PID does not provide
HSD/LSD descriptor.
Options are:
Data1, Data2 / LSD.
DSNG-CA
Encryption Mode
DSNG Encryption Mode Selection
Selects the DSNG-Conditional Access (CA) encryption mode.
Options available:
BISS-Mode 1
BISS-E – Clear SW:
BISS-E – Injected ID
BISS-E – Buried ID
EVEN-ODD