DataPage MK2 (USA) Desktop UHF Radio Paging System
DPUSA 02/00
14
Issue 2
5: Changing the Password
Whilst at the main programming menu screen, press (
Screen will change to:
ENTER
PASSWORD:
?
Type in current password and press ENTER.
Screen will change to:
NEW PASSWORD:
?
Type in new password and press ENTER.
Screen will change to:
CONFIRM
PASSW’D:
?
Re-type the new password and press ENTER.
Screen will now read:
Password
Updated OK
The new password is now successfully stored.
To return to the pager entry screen press ENTER or CANCEL when at the main programming menu.
Problems and Fault Finding
Check that there is power at the mains socket.
Check that the pagers are at least 3 meters from the transmitter and aerial. Under certain conditions it is
possible to flood the pager receivers and corrupt the data received.
Check that the pagers have the battery installed with the correct polarity and are correctly powered up.
Check that the aerial is correctly installed.
Check the Base ID on the password menu matches the system data. Check the transmission baud rate matches
the system data.
Serial Port: check and re-check the data cable connections. This, together with an incorrect signaling format,
result in more faults than any other problem. Check the port configuration on the password menu.
Check that the communications Baud rate set on the host matches the system.
Telephone Interface: check the cable connections. Check the port is active on a 2 wire DTMF system with the
aid of a standard telephone. Check the base ID and transmission baud rate on the password menu.