DataPage MK2 (USA) Desktop UHF Radio Paging System
DPUSA 02/00
11
Issue 2
You may enter a number in the range 1-4 which will correspond to the pager beep codes A, B, C, D respectively.
Note, not all pagers are equipped to respond to transmitted beep codes. Press ENTER to confirm or CANCEL to
return to the start.
After pressing ENTER, the screen display will change to prompt for the transmission data speed:
TRANSMIT SPEED:
>
1200 bps
Press key 1 to select 512 baud, key 2 to select 1200 baud or key 3 to select 2400 baud. Press ENTER to return
to the programming menu.
2: Inputs
Press key 2. The screen changes to:
INPUT COUNT 0-2
>
Select the number of dry contacts required: either 0, (none), 1 (DC1) or 2 (DC1 and DC2).
After pressing ENTER, the screen will change to:
ACTIVATE STATE:
: Normally Open
Pressing key 1 will display
Normally Open
Pressing key 2 will display
Normally Closed
Pressing key 3 will display
Change of State
After making your selection, press ENTER to store.
Display will change to:
TRIG. TIME 0-15:
>
This indicates the time that the contacts must remain in the active state to effect a trigger. A value of between 0
and 15 can be entered, which represents blocks of 0.25 seconds (approximately). Therefore, a value of 14 would
equate to 3.5 seconds.
After making your selection, press ENTER to store; display will change to:
REPT. TIME 0-15:
>
For added safety, when in Normally Open Mode the message is repeated whilst the contact remains in the
closed state. This screen allows you to select the time gap between each repeat transmission. Each unit
represents a block of 10 seconds.
After making your selection, press ENTER to store; display will change to:
INPUT 1 PAGER
>