![SCI MM-380A Скачать руководство пользователя страница 93](http://html1.mh-extra.com/html/sci/mm-380a/mm-380a_operation-manual_1217109093.webp)
MM-380A
14. Specification
14-2
Target
Specification
Measurement
accuracy
Current:
RMS
<2.000kA, 20.00kA or 200.0kA range>
Single-phase AC welding power supply, transistor
welding power supply
±
(1%rdg+9dgt)
AC inverter welding power supply, DC inverter
welding power supply
±
(1%rdg+15dgt)
<6.00kA or 60.0kA range>
Single-phase AC welding power supply, transistor
welding power supply
±
(1%rdg+3dgt)
AC inverter welding power supply, DC inverter
welding power supply
±
(1%rdg+5dgt)
Peak value
<2.000kA, 20.00kA or 200.0kA range>
Single-phase AC welding power supply, transistor
welding power supply
±
(1%rdg+9dgt)
AC inverter welding power supply, DC inverter
welding power supply
±
(1%rdg+20dgt)
<6.00kA or 60.0kA range>
Single-phase AC welding power supply, transistor
welding power supply
±
(1%rdg+3dgt)
AC inverter welding power supply, DC inverter
welding power supply
±
(1%rdg+7dgt)
Current
Detection method Toroidal coil
(Recommended:
MB-800K
,
MB-400K
,
MB-45F
)
Measurement
range
6.00V range:
0.30 to 6.00V
20.0V range:
1.0 to 20.0V
Measurement
item
Arithmetic mean RMS/maximum (peak)
Voltage
Measurement
accuracy
±
(1%rdg+3dgt)
MA-520
4.90 to 98.06N, 0.50 to 10.00kgf, 1.10 to
22.04lbf
MA-521
49.0 to 980.6N, 5.0 to 100.0kgf, 11.0 to
220.4lbf
MA-710A
MA-770A
490 to 9806N, 50 to 1000kgf, 110 to
2204lbf
MA-522
MA-711A
MA-771A
245 to 4903N, 25 to 500kgf, 55 to 1102lbf
Measurement
range
Rated
setting
5% to 100% of rated setting
Measurement
time
1 to 6000ms
Force
Measurement
accuracy
±
(load cell F/S error+2%rdg+29dgt)