MM-380A
8. Operation Screens
8-12
i.
WAVEFORM (FORCE) screen
No.
Item
Description
(1)
SCH.#
Shows the measurement condition number used (1 to
127). On the other hand, you can change conditions by
selecting this field with the encoder and turning the
encoder clockwise or counterclockwise. The details of the
conditions can be set using the SETUP (1) to (3) screens.
(2)
Waveform
display
*1
Shows the force, current and trigger waveforms.
(3)
Force time
*1
(Continued to
next page)
Shows the following items: ((1) to (6) correspond to the
numbers in the figure on the next page.)
Force 1 (FORCE1)
*2
:
Mean force over force calculation interval 1
Force 2 (FORCE2)
*2
:
Mean force over force calculation interval 2
Force Time (FORCE)
*2
:
Time from when the force signal exceeds the force start
level to when the signal reaches the force end level
Force Start Time (ELECTR CLOSE) (1):
Time from the force external trigger input to when the force
signal exceeds the force start level
Squeeze Time (SQUEEZE) (2):
Time from the force external trigger input to the start of
current flow
Force Stabilization Time (SQZ DELAY) (3):
Time from when the force signal exceeds the force start
level to the start of current flow
Hold Time (HOLD) (4):
Time from the end of current flow to when the force signal
falls below the fall level
Current Start Time (TIME OF FORCE) (5):
Time from when the force signal exceeds the rise level to
the start of current flow
Force Completion Time (SQZ ADJUST) (6):
Time from the force external trigger input to when the force
signal exceeds the rise level
(2)
(4)
(1)
(3)