3
P40-R I&O Manual
IM120801
RD: AUG 2013
RL: 1D
TABLE OF CONTENTS
TOPIC .........PAGE
IMPORTANT INFORMATION - READ FIRST
OPERATING INSTRUCTIONS
........................4
SAFETY
WARNINGS.......................................5
START UP ‘SMOKE’
........................................6
FLUE
VENTING
.........................................6, 19
GAS
CONNECTION
...................................7, 25
CLEARANCE TO COMBUSTIBLES
....... 7 - 10
Clearances: Figures & Table................... 8 - 9
STACKING HEIGHT SIGN
............................9
VENT CLEARANCE
........................ 10, 20 - 22
1. APPLICATION ................................................11
2. LABOR
REQUIREMENTS .............................12
3. INSTALLATION IN AIRCRAFT HANGARS ...12
4. INSTALLATION IN COMMERCIAL
GARAGES ......................................................12
5. INSTALLATIONS OTHER THAN
SPACE HEATING...........................................12
6. PRE-INSTALLATION
SURVEY......................13
7. MOUNTING
CLEARANCES...........................13
8.
SERVICE
CLEARANCE................................13
9. HEATER PLACEMENT GUIDELINES ...........14
10. HEATER INSTALLATION ..............................15
10-A SEISMIC RESTRAINT ................................18
10-B HIGH WIND RESTRAINT ...........................18
11. FLUE VENTING............................................. 19
Side Wall Horizontal Vent.................... 20 - 21
Horizontal Vent Terminal Location ............. 22
Vertical
Vent
Through Roof ....................... 23
12. COMBUSTION AIR REQUIREMENTS ......... 24
13. GAS SUPPLY & CONNECTION ................... 25
ORIENTATION OF FLEXIBLE GAS
CONNECTION
(if applicable)
.........................26
14. GAS CONVERSION .......................................27
15. ELECTRICAL AND THERMOSTAT .............. 27
TOPIC ……...PAGE
16. HIGH ALTITUDE INSTALLATION ...................27
17. LIGHTING INSTRUCTIONS ...........................27
18. RECOMMENDED MAINTENANCE ................ 28
19. WIRING DIAGRAMS................................ 29 - 30
20. SEQUENCE OF OPERATION .......................31
21. TROUBLESHOOTING GUIDE.........................32
22. SPARK IGNITION CIRCUIT ............................34
SPARK IGNITER SET UP ...............................34
23. FLAME SENSING CIRCUIT ...........................35
24. START– UP / COMMISSIONING SHEET........36
PRODUCT DIMENSIONS & DATA
25. HEATER DIMENSIONS / WEIGHTS ……….38
26. HIGH ALTITUDE & ORIFICE CHART..............39
28. OPTIONAL ACCESSORIES..................... 40 - 41
29. REPLACEMENT PARTS LIST ................ 43 - 44
WARRANTY STATEMENT ............BACK PAGE
FIGURES:
FIG 1 - CLEARANCE TO COMBUSTIBLES (3D VIEW) ............8
FIG 2 - CLEARANCE TO COMBUSTIBLES (END VIEW) .........9
FIG 3 - SERVICE CLEARANCE...............................................13
FIG 4 - TYPICAL HEATER SUSPENSION (END VIEW) .........16
FIG 5 - TYPICAL HEATER SUSPENSION (3D VIEW) ............17
FIG 6 - HEATER DIMENSIONS & SUSPENSION ANGLE
OPTIONS ....................................................................17
FIG 7 - SEISMIC RESTRAINT..................................................18
FIG 8 - HIGH WIND RESTRAINT.............................................18
FIG 9 - HORIZONTAL SIDE WALL VENT CLEARANCES ......20
FIG 10 - HORIZONTAL SIDEWALL VENT OFFSET................20
FIG 11 - LOCATION OF HORIZONTAL VENT TERMINAL .....22
FIG 12 - VERTICAL ROOF VENT ...........................................23
FIG 13 - MINIMUM LENGTH VERTICAL ROOF VENT ...........23
FIG 14 - CORRECT ORIENTATION OF FLEXIBLE GAS ........26
FIG 15 - INCORRECT ORIENTATION OF FLEXIBLE GAS ....26
WIRING DIAGRAMS ..........................................................29, 30
FIG 16 - HEATER DIMENSIONS .............................................38
P40-R