4 Planning
Room temperature control
Radiant tube heating-systems must be equipped with
a temperature control.
Section heating is allowed without temperature control.
Position of suspension
Suspension height
Radiant tubes must be positioned so that no one in
the radiation area is exposed to an extreme high heat
level. This is ensured when the minimum suspension
heights shown in the following table are adhered to:
Tab 1: Minimum suspension heights
Key:
A = Minimum height when hanging horizontally
B = Minimum height when hanging angled
Type
a
[cm]
c
[cm]
infra
calor
infra
calor
15 U
110
20
10
50
15
15
20 U
110
20
10
50
15
15
30 U
130
20
10
50
15
15
40 U
170
25
10
50
25
15
b
[cm]
d
[cm]
Tab 2: Safe distances
Key:
a = Minimum radial safety distance (inside radiation area)
b = Minimum upper safety distance when hanging horizontally
c = Minimum upper safety distance when hanging angled
d = Minimum lateral distance to supply pipes outside radiation area
Distances to flammable materials in the
radiant area
Radiant tubes must be positioned so that the surface
temperature of
components with flammable materials,
flammable equipment, stored flammable materials
not exceed 65°C above ambient.
Do not place articles on or against
this appliance.
Do not use or store flammable
materials near this appliance.
Do not spray aerosols in the
vicinity of this appliance while it is
in operation.
Fig 3: Suspension heights and distances for horizontal
application
Fig 4: Suspension heights and distances for angled
application
Direction of radiation
Radiant tubes infraSchwank D / calorSchwank D can
be positioned horizontal or at an angle (max. 30° from
vertical). For this purpose suspension steel chains
and cables are installed at the suspension brackets.
Nominal
thermal load in
MJ/h (type)
Suspension height in m
(max. radiation 200 W/m
2
)
A = horizontal
B = angled
(30°)
60
(15U)
3.5m 3.1m
75.9
(20U)
4.0m 3.6m
115.9
(30U)
4.8m 4.3m
155.8
(40U)
5.5m 4.9m