LEAK TEST:
Now that the heater is assembled, for your safety you must perform
a leak test of all connections and hoses,
Mix equal parts of water and soap, brushing mixture on all joints.
1. Ensure that the heater gas control knob is fully closed by turning
completely clockwise.
2. Open cylinder valve
3. Apply the soap solution generously to all connections and hoses.
If you detect bubbles, there
IS
a leak. Close cylinder valve completely.
Re-tighten the leaking connection and repeat leak test process, until
ALL
leaking has ceased, no matter
how small.
If the leak cannot be repaired permanently, close the cylinder valve completely and contact a qualified
and licensed gas technician.
•
Lift the cylinder cover up from the base of the heater.
•
Connect the regulator hose to the hose coming down
through the post.
•
Install a full gas cylinder on to the base
•
Connect the gas regulator hose to the QCC 1 cylinder valve
by turning the knob manually in a clockwise direction.
•
DO NOT use a tool, hand tighten only
•
Replace the cylinder cover.