background image

GP-M403-BX-04B 

4003 / 4403 Manual 

    RD: March 2006  

R.L. 4B 

KH 

 

NOTICE: 

 

The Manufacturer. reserves the right to make changes to equipment and 
specifications without obligation or  
notification. 
 
This publication, or parts thereof, may not be reproduced in any form, 
without prior written consent from the manufacturer.   
Unauthorized use or distribution of this publication is strictly prohibited. 
 
Schwank / InfraSave 
5285 Bradco Boulevard 
Mississauga, Ontario, 
L4W 2A6 
Phone: (905) 712-4766 
Fax: (905) 712-8336 
1-866-361-0417 
 
PO Box 988, 2 Schwank Way 
Waynesboro, Georgia, 
USA  30830 
Phone: (706) 554-6191 
Fax: (706) 554 9390 
1-877-446-3727 
 
e-mail: [email protected] 

www.schwankheaters.com 

 

e-mail: [email protected] 

www.infrasave.com

 

Содержание 4003 series

Страница 1: ...appliance If you smell Gas Extinguish any open flames Don t touch electrical switches Call your Gas supplier immediately FIELD CONVERTIBILITY The conversion shall be carried out in accordance with the requirements of the authorities having jurisdiction and in accordance with the requirements of the B149 1 latest edition INSTALLATION CODE in Canada and the ANSI Z223 1 latest edition in the U S A Me...

Страница 2: ... without prior written consent from the manufacturer Unauthorized use or distribution of this publication is strictly prohibited Schwank InfraSave 5285 Bradco Boulevard Mississauga Ontario L4W 2A6 Phone 905 712 4766 Fax 905 712 8336 1 866 361 0417 PO Box 988 2 Schwank Way Waynesboro Georgia USA 30830 Phone 706 554 6191 Fax 706 554 9390 1 877 446 3727 e mail info schwankheaters com www schwankheate...

Страница 3: ...IFICATIONS 5 4 MAIN COMPONENTS FOR ASSEMBLY 6 5 ASSEMBLY INSTRUCTIONS 7 5 1 CONNECTION AND TESTING 10 6 A SAFE LOCATION FOR THE HEATER 11 TOPIC PAGE NUMBER 6 1 CLEARANCE TO COMBUSTIBLES 11 7 OPERATING LIGHTING INSTRUCTIONS 12 8 TROUBLESHOOTING 13 8 1 STORAGE 14 8 2 MAINTENANCE 14 8 3 SAFETY 14 9 LIMITED WARRANTY 15 SERIES 4003 4403 INFRA RED PORTABLE PATIO HEATER ...

Страница 4: ...GP M403 BX 04B 4003 4403 Manual RD March 2006 R L 4B KH ...

Страница 5: ...ng cylinder Gas connections on the heater are leak tested at the factory prior to shipment For your safety a complete gas tightness check of all connections and hoses must also be performed at the installation site prior to This appliance is an infrared transportable patio deck and garden heater for operation with LPG Liquefied Petroleum Gas The burner is controlled and adjusted by the gas control...

Страница 6: ...t not exceed 125 psi A Minimum supply pressure of 11 0 w c is required to maintain correct burner input The pressure regulator and hose assembly supplied with the appliance MUST be used Any replacement pressure regulator and hose must conform to standards specifications of the Manufacturer and all local codes The installation must conform with local codes or in the absence of local codes with Nati...

Страница 7: ...line LPG Regulator with 22 inch Hose and QCC Fittings Aluminum Reflector 5 pc Sectional 4 ea M6 x 20 mm Bolts for Burner Assembly Upper Post 6 ea M6 x 35 mm long with M6 Nuts for Post Brackets 3 ea M8 x 15 mm long bolts for Post Bracket to Cylinder Base 12 ea 1 4 acorn nuts for attaching reflector components 12 ea 1 4 washers for attaching reflector components 12 ea 1 4 bolts for assembling cylind...

Страница 8: ...he 3 post mounting brackets on the Cylinder Base as shown Use 3 M8 x 15 mm bolts to secure brackets to the base Place the post onto the top of the post brackets aligning pre drilled holes as shown Use 6 M6 x 35 mm bolts washers nuts to at tach post to post brackets Tighten securely Page 7 ...

Страница 9: ... RD March 2006 R L 4B KH c hw S an k an w Sc h k Slide the cylinder cover onto the post Slide the hose through inside of post Then fasten burner onto post with the 4 Phillips 10 mm mechanical screws provided ASSEMBLY CONTINUED Page 8 ...

Страница 10: ...flector Place a steel washer over each bolt on the burner top 1pc or 5pcs Assemble the reflector pieces to the centre piece using the small washers and the acorn nuts Secure with M8 125 butterfly wing nuts 5 piece section reflector 32 dia one piece option 32 dia 32 5pcs Page 9 ...

Страница 11: ...k Close cylinder valve completely Re tighten the leaking connection and repeat leak test process until ALL leaking has ceased no matter how small If the leak cannot be repaired permanently close the cylinder valve completely and contact a qualified and licensed gas technician Lift the cylinder cover up from the base of the heater Connect the regulator hose to the hose coming down through the post ...

Страница 12: ...mbustibles as shown in figure 12 below Install heater on a levelled solid and stable surface Do not install in an explosive environment Keep away from areas where gas vapours are present or inflammable liquids are stored or used In case of high winds completely shut off the heater and the cylinder gas valve Remove reflec tor dome Do not move the heater when it is hot The clearances to combustibles...

Страница 13: ... turn 3 Fully depress control knob to allow gas flow to the burner keeping this knob depressed while repeatedly pressing the Piezo igniter button until the burner lights If the burner does not light up after 10 seconds release the control knob and turn clockwise to shut off the heater completely Wait 5 Minutes If the igniter is defective you may light the burner manually by inserting a match throu...

Страница 14: ...n light pilot manually with a match or taper Burner will not stay on Debris or dirt around the pilot Loose connections Clean pilot area Tighten Connections Thermocouple faulty Gas leak in the line Lack of fuel pressure Replace Thermocouple Check connections Near empty fuel cylinder Low Burner Flame Cylinder is low on fuel Check replace empty LPG gas cylinder Check for restricted or plugged orifice...

Страница 15: ...der indoors Store gas cylinder in a well ventilated area For more compact storage and to avoid damage the reflector may be removed 8 2 PREVENTATIVE CARE AND MAINTENANCE The burner area is likely to attract spiders especially inside orifices Once a year the heater should be inspected for spider webs insects and debris around burners and orifices Plugged injectors or orifices will obstruct the gas f...

Страница 16: ...GP M403 BX 04B 4003 4403 Manual RD March 2006 R L 4B KH ...

Страница 17: ...roperlyinstalled misused exposed to or damaged by neg ligence accident corrosive or contaminating atmosphere water excessive thermal shock impact abrasion normal wear due to use alteration or operation contraryto the owner s manual or if the serial number has been altered defaced or removed This warranty shall not apply if the input to the heating product exceeds by more than 2 of the rated input ...

Отзывы: