29
English
Press the
▲
key to increase the intensity.
Press the
▼
key to decrease the intensity.
The intensity of each channel is displayed on the screen.
The intensity can be set between 0 and 20 mA in steps of 0.1 mA.
By keeping the
▲▼
keys pressed, the intensity will increase/decrease more rapidly.
The program starts after increasing the intensity. The clock symbol then
appears on the display and indicates the remaining therapy time.
The AS SUPER 4 digital constantly monitors the correct connection between the
needles, cables and device. The device does not permit the intensity to exceed
4 mA if the circuit is not closed. The intensity then returns to 0. This is also indicated
by an acoustic signal. Please refer to the chapter “Malfunctions”.
Switching OFF the device
Once the program is completed, the intensities automatically return to 0.
This is also indicated by an acoustic signal. Press the key to switch OFF the
device. You can then remove the crocodile clips from the needles and remove the
needles from the patient’s skin.
Pausing the stimulation
Press the
E
key during the running stimulation to pause
the stimulation. The word “PAUSE” then flashes on the dis-
play. Press the
E
key again to restart the stimulation. If you
do not restart the stimulation within 2 minutes, the device
switches OFF automatically.
Stopping the stimulation
Press the
P
key at any time to stop the stimulation. The intensity of all channels
returns to 0. Press the key to switch OFF the device. You can then remove the
crocodile clips from the needles and remove the needles from the patient’s skin.
Keylock
Enable keylock:
»
Device Adjustment (program and sure to adjust the intensity).
»
Press buttons 1 + 2
simultaneous.
The device is locked, the key symbol appears in the display.
Содержание AS SUPER 4 digital
Страница 37: ...37 English ...
Страница 38: ...38 schwa medico Operating Manual AS SUPER 4 digital ...
Страница 39: ...39 English ...