Adjustment Work
Single Arm Pantograph WBL 85 Balfour Beatty
Page 32
WBL 85-15kV
10.9
Adjustment of Contact Force Monitoring System
Instructions:
❑
Loosen securing screws (1) of 3/2-way valve
❑
Slide valve (5) down all the way
❑
Switch pantograph in raising position
❑
Apply load on contact strip (2) vertically, until lever (3) contacts the regulating
screw (4). (The pan must have been adjusted before – see 10.8.)
❑
Slide the valve (5) upwards over oblong holes until the lifter of valve (5) is
actuated by the pan spring, causing the signal of the compressed air horn to
cease.
❑
Tighten screws (1).
❑
Check: Tension and release contact strip. As soon as the lever (3) hits the
regulating screw (4), the acoustic signal must cease. Whenever
lever (3) moves away from screw (4), the signal horn must sound.
Securing Screw (1)
Valve (5)
Lever (3)
Contact Strip (2)
Regulating Screw (4)