![SCHUNK WBL 85 Balfour Beatty Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/schunk/wbl-85-balfour-beatty/wbl-85-balfour-beatty_maintenance-and-operating-manual_1215849013.webp)
5.4
Installation of Electrical Equipment
5.4.1
High Voltage Connection
The high voltage earthing has to be made on the connecting strap (1) connection. The
connecting spot needs to be well greased with conducting grease.
WBL 85-15kV
Assembly
Single Arm Pantograph WBL 85 Balfour Beatty
Page 13
5.5
Mounting of Pneumatic Air Connection
The pneumatic connection between vehicle and pantograph has to be accomplished
on the connections (1) and (2). Both connection have a 1/4" inside thread.
Connection (1):
Connection for pantograph-airbellowdrive
Connection (2):
Connection for latch
2
1