![SCHUNK VERO-S NST3 400-250 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/schunk/vero-s-nst3-400-250/vero-s-nst3-400-250_assembly-and-operating-manual_1215848019.webp)
Assembly
Centering
Reference B
Alignment
Reference C
Alignment with two alignment holes
4.3 Mounting and connecting the clamping station
To prevent chip accumulation, a sufficient number of protective
covers for covering the mounting screws is provided in the
accessory kit.
WARNING
Risk of injury due to brass bore hole cover plate ejecting during
a turning application of the clamping station.
The brass bore hole cover plates of the mounting screws may
only be used for stationary applications of the clamping station.
Flatness and distances
In order to assemble the clamping station, the clamping surface
must have a flatness of ≤ 0.03 mm (based on the entire support
areas of the clamping station). The clamping zone must have
sufficient rigidity in order to ensure the relative flatness of the
clamping modules. If several clamping stations are interlinked,
make sure that the flatness and height deviation of the locating
surfaces between modules (based on a 200 mm gauge for bore
holes) is ≤ 0.03 mm. The gauge deviation between the separate
clamping stations must not exceed ± 0.015 mm from module to
module.
Redundancy
For the sake of conformity, clamping pins with positioning
accuracy in one direction (SPB 40) should be used for clamping
modules inside a clamping station or multiple linked clamping
stations that are more than 160 mm apart or that do not show a
positioning tolerance of ± 0.01 mm. For the clamping areas that
are not intended for aligning the device or pallet, clamping pins
with centering clearance (SPC 40) can be used (also refer to
chapter "Clamping pins"
).
19
02.00 | NST3 | VERO-S quick-change pallet system | en | 1344366
Содержание VERO-S NST3 400-250