Trouble shooting
10 Trouble shooting
The clamping area does not unlock
Possible cause
Corrective action
Faulty air connections
Check air supply
Pressure drops below minimum
Check operating pressure (min. 5 bar)
Component is broken, e.g. through
overloading
Replace module or send it to SCHUNK for
repair
Tensile load to the clamping pin is too
high
Reduce load
The clamping area does not unlock perfectly
Possible cause
Corrective action
Pressure drops below minimum
Check operating pressure (min. 5 bar)
Module has not been operated with
lubrified air
Install a maintenance unit with oiler
The hose diameter is below minimum
Required hose diameter, see chapter "General
assembly notes"
The pneumatic port for "turbo effect" is
still actuated with pressure
Vent the connection
The quick change pallet system no longer opens quietly
Possible cause
Corrective action
The clamping faces on the clamping slides
and on the clamping pin are dirty
Remove the clamping pin and clean the
clamping faces on the clamping slides and on
the clamping pin.
31
06.00 | NSA plus 120; NSA plus 160 | VERO-S quick-change pallet system | en |