Maintenance
22
02.00 | TCU-Z | Assembly and operating manual | en | 389464
6.4.2 Variant without locking (OV)
Position of the item numbers
WARNING
Risk of injury due to unexpected movements!
If the power supply is switched on or residual energy remains in
the system, components can move unexpectedly and cause
serious injuries.
•
Before starting any work on the product: Switch off the power
supply and secure against restarting.
•
Make sure, that no residual energy remains in the system.
Ø
Disconnect cable connections.
Ø
Remove compressed air lines.
Ø
Remove product from handling device.
Ø
Remove screws (51) and separate product form the adapter
plate.
Ø
Remove screws (52) from the housing-top (02).
Ø
Remove screws (53) then remove bolt (09).
Ø
Separate housing top (22) from the flange bottom (01).
6.5 Servicing and assembling the product
Position of the item numbers
WARNING
Risk of injury due to spring forces!
The cover is under spring tension.
•
Carefully disassemble the product.
Maintenance
• Remove screws (52) from the flange-bottom (01) and replace
shear-pads (15).
• Clean all parts thoroughly and check for damage and wear.
• Treat all greased areas with lubricant.
Lubricants/Lubrication points (basic lubrication)
• Oil or grease bare external steel parts.
• Replace all wear parts / seals.
– Position of the wearing parts
Assembly
Assembly takes place in the opposite order to disassembly