background image

Maintenance

22

02.00 | TCU-Z | Assembly and operating manual | en | 389464

6.4.2 Variant without locking (OV)

Position of the item numbers 

Assembly drawing

 [

}

 23]

 WARNING

Risk of injury due to unexpected movements!

If the power supply is switched on or residual energy remains in
the system, components can move unexpectedly and cause
serious injuries.

Before starting any work on the product: Switch off the power
supply and secure against restarting.

Make sure, that no residual energy remains in the system.

Ø

Disconnect cable connections.

Ø

Remove compressed air lines.

Ø

Remove product from handling device.

Ø

Remove screws (51) and separate product form the adapter
plate.

Ø

Remove screws (52) from the housing-top (02).

Ø

Remove screws (53) then remove bolt (09).

Ø

Separate housing top (22) from the flange bottom (01).

6.5 Servicing and assembling the product

Position of the item numbers 

Assembly drawing

 [

}

 23]

 WARNING

Risk of injury due to spring forces!

The cover is under spring tension.

Carefully disassemble the product.

Maintenance

• Remove screws (52) from the flange-bottom (01) and replace

shear-pads (15).

• Clean all parts thoroughly and check for damage and wear.
• Treat all greased areas with lubricant.

Lubricants/Lubrication points (basic lubrication) 

 [

}

 21]

• Oil or grease bare external steel parts.
• Replace all wear parts / seals.

– Position of the wearing parts 

Assembly drawing

 [

}

 23]

– Seal kit 

Seal kit

 [

}

 7]

Assembly

Assembly takes place in the opposite order to disassembly

Содержание TCU-Z

Страница 1: ...Translation of the original manual Assembly and operating manual TCU Z Tolerance Compensation Unit...

Страница 2: ...ations for the purpose of technical improvement Document number 389464 Version 02 00 05 02 2020 en SCHUNK GmbH Co KG All rights reserved Dear Customer thank you for trusting our products and our famil...

Страница 3: ...9 2 7 Personal protective equipment 10 2 8 Notes on safe operation 10 2 9 Transport 10 2 10 Disposal 11 2 11 Fundamental dangers 11 2 11 1 Notes on particular risks 11 3 Technical data 12 3 1 With Loc...

Страница 4: ...tervals 20 6 3 Lubricants Lubrication points basic lubrication 21 6 4 Disassemble the product 21 6 4 1 Variant with locking MV 21 6 4 2 Variant without locking OV 22 6 5 Servicing and assembling the p...

Страница 5: ...manual Illustrations in this manual are provided for basic understanding and may differ from the actual product design In addition to these instructions the documents listed under Applicable document...

Страница 6: ...TCU Z 200 1 1 4 Variants This operating manual applies to the following variations TCU Z Without locking TCU Z With locking 1 2 Warranty If the product is used as intended the warranty is valid for 24...

Страница 7: ...nsion cables if necessary For information regarding which accessory articles can be used with the corresponding product variants see catalog data sheet 1 4 1 Seal kit ID No of the seal kit Seal kit fo...

Страница 8: ...2 2 Not intended use It is not intended use if the product is used for example as a pressing tool stamping tool lifting gear guide for tools cutting tool clamping device or a drilling tool Any utiliza...

Страница 9: ...ries and significant property damage All work may only be performed by qualified personnel Before working with the product the personnel must have read and understood the complete assembly and operati...

Страница 10: ...handling of the personnel Incorrect handling and assembly may impair the product s safety and cause serious injuries and considerable material damage Avoid any manner of working that may interfere wi...

Страница 11: ...s Before commissioning the product take appropriate protective measures to secure the danger zone Disconnect power sources before installation modification maintenance or calibration Ensure that no re...

Страница 12: ...00 125 160 200 Weight kg 0 18 0 25 0 48 0 85 1 63 2 75 permissible operating temperature C 10 to 90 Pressure medium Compressed air compressed air quality according to ISO 8573 1 7 4 4 Min pressure bar...

Страница 13: ...SCHUNK can provide an adapter plate with hole pattern for mounting holes The adapter plate 2 is mounted to the robot 1 and to the TCU Z 3 see our catalog for mounting data SCHUNK gripper types PGN pl...

Страница 14: ...ing surface to which the product is mounted Requirements for evenness of the mounting surface Dimensions in mm Edge length Permissible unevenness 100 0 02 100 0 05 4 2 1 Assembly at the robot Mounting...

Страница 15: ...e Nm 1 27 3 0 10 1 10 1 24 6 24 6 48 maximum screw in depth Z mm 3 2 6 5 6 5 11 5 13 5 10 5 14 5 cylindrical pin fit diameter 3 h6 4 h6 5 h6 5 h6 6 h6 6 h6 8 h6 max fitting depth mm 4 6 6 6 8 10 12 4...

Страница 16: ...uirements for the air supply Technical data 12 1 Main connections Hose connection A lock B unlock Designation TCU Z 64 80 100 125 160 200 Thread in the main air connections M5 G1 8 Hose connection Con...

Страница 17: ...s For the exact type designations of suitable sensors please see the catalog data sheet For technical data for the suitable sensors see Assembly and Operating Manual and catalog data sheet The Assembl...

Страница 18: ...nut available slide the sensor according to dimension I1 into the groove 2 see following table Turn the sensor 1 into the groove 2 OR Slide the sensor 1 into the groove 2 until the sensor 1 stops at t...

Страница 19: ...Readjust or change sensor 5 3 Product does not execute the full stroke for the locking Possible cause Corrective action Dirt between cylinder and cylinder cover Disassemble and clean the product Pres...

Страница 20: ...ingly Interval Mio cycles for TCU Z Maintenance work 50 100 125 160 200 4 3 2 Clean all parts thoroughly check for damage and wear if necessary replace seals and wearing parts Servicing and assembling...

Страница 21: ...the power supply is switched on or residual energy remains in the system components can move unexpectedly and cause serious injuries Before starting any work on the product Switch off the power supply...

Страница 22: ...separate product form the adapter plate Remove screws 52 from the housing top 02 Remove screws 53 then remove bolt 09 Separate housing top 22 from the flange bottom 01 6 5 Servicing and assembling the...

Страница 23: ...Maintenance 02 00 TCU Z Assembly and operating manual en 389464 23 6 6 Assembly drawing Assembling of the variant without locking OV...

Страница 24: ...Assembly and operating manual en 389464 Assembling of the variant with locking MV Wearing part replace during maintenance Included in the seal kit Seal kit can only be ordered completely only for TCU...

Страница 25: ...n Unit TCU Z pneumatic ID number 324766 324784 324798 324820 324838 324856 1377682 The partly completed machine may not be put into operation until conformity of the machine into which the partly comp...

Страница 26: ...equirements 1 1 1 Definitions X 1 1 2 Principles of safety integration X 1 1 3 Materials and products X 1 1 4 Lighting X 1 1 5 Design of machinery to facilitate its handling X 1 1 6 Ergonomics X 1 1 7...

Страница 27: ...ng movable guards X 1 4 2 3 Adjustable guards restricting access X 1 4 3 Special requirements for protective devices X 1 5 Risks due to other hazards 1 5 1 Electricity supply X 1 5 2 Static electricit...

Страница 28: ...ety requirements for certain categories of machinery X 2 1 Foodstuffs machinery and machinery for cosmetics or pharmaceutical products X 2 2 Portable hand held and or guided machinery X 2 2 1 Portable...

Отзывы: