6.3 Lubricants/Lubrication points (basic lubrication)
SCHUNK recommends the lubricants listed.
During maintenance, treat all greased areas with lubricant. Thinly
apply lubricant with a lint-free cloth.
Lubricant point
Lubricant
Metallic sliding surfaces
microGLEIT GP 360
All seals
Renolit HLT 2
Bore hole at the piston
Renolit HLT 2
6.4 Disassemble the product
6.4.1 Variant with locking (MV)
Position of the item numbers
WARNING
Risk of injury due to unexpected movements!
If the power supply is switched on or residual energy remains in
the system, components can move unexpectedly and cause
serious injuries.
•
Before starting any work on the product: Switch off the power
supply and secure against restarting.
•
Make sure, that no residual energy remains in the system.
Ø
Disconnect cable connections.
Ø
Remove compressed air lines.
Ø
Remove product from handling device.
Ø
Remove screws (51) and separate product form the adapter
plate.
Ø
Remove screws (52) from the housing-top (02).
Ø
WARNING Danger of injury due to spring forces! The cylinder
piston is under spring tension.
Remove screws (53) then
remove bolt (09).
Ø
Separate housing top (02) from the flange bottom (01).
Ø
Unscrew screws (49) and remove cylinder cover (04).
Ø
Remove cylinder piston (03) from the housing-top (02)