Assembly
26
04/STM-560V/en/2010-12-10/SW
7
Assembly
7.1
Mechanical connection
WARNING
Risk of injury when the machine/system moves
unexpectedly!
Switch off power supply.
NOTICE
Malfunctions due to mechanical stress in the housing
possible
Observe the requirements for the evenness of the mounting
surface.
The values relate to the entire bolting surface.
diameter [mm]
Permissible unevenness [mm]
< 100
< 0,02
> 100
< 0,05
Table 15 Requirements for levelness of the bolting surface
Depending on the load, the STM develops a very large heat
quantity that needs to be dissipated:
Mount the motor on heat-conducting materials.
To achieve the IP protection class 40:
Design the connection structure so that no chips, cooling
water or dirt can enter the STM's connection area from the
working area.
Note
If the unit has to be referenced via the measuring system's index
track, and if the moving range is limited when the STM is
installed, make sure that the basic carrier is aligned correctly in
the machine. (see Figure 5, page 27)
Align the zero point markings of the rotor and the base body
so that they are at right angles on top of each other.
Check the
evenness of the
bolting surface
Preconditions
Содержание STM 560V Series
Страница 2: ...2 04 STM 560V en 2010 12 10 SW...
Страница 49: ...Start up 04 STM 560V en 2010 12 10 SW 49 Figure 38 6 Do not set up a motor holding brake Figure 39...
Страница 67: ...Drawing 04 STM 560V en 2010 12 10 SW 67 13 Drawing 13 1 STM 135 Figure 63 Dimensions of the STM torque motor...
Страница 68: ...Drawing 68 04 STM 560V en 2010 12 10 SW 13 2 STM 170 Figure 64 Dimensions of the STM torque motor...
Страница 69: ...Drawing 04 STM 560V en 2010 12 10 SW 69 13 3 STM 210 Figure 65 Dimensions of the STM torque motor...