![SCHUNK SFL 25 Series Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/schunk/sfl-25-series/sfl-25-series_assembly-and-operating-manual_1216044037.webp)
Maintenance
05.00 | SFL | Assembly and operating manual | en | 389398
37
Assembling the basic modules GKM and FAN
Ø
Turn the rectangular section of the rotor (53) with the longer
side towards the center of the air connections A and B.
Ø
Position the stop (81) with the magnets (141):
- for 090 variant: One magnet points towards the 90° position
and the other one towards the 180° position.
for 180 variant: One magnet points towards the 0° position and
the other one towards the 180° position.
Ø
Put the GKM basic module onto the FAN rotor drive and tighten
it using the screws (104).
Ø
Connect the compressed air connections.
7.8 Screw and nut tightening torques
Position of the item numbers,
Designation
Tightening torque [Nm]
SFL 25
SFL 40
SFL 64
Item 101
0.7
1.2
3.1
Item 104
0.7
1.2
3.1
Item 140
0.3
1.2
4
Item 121
0.8
1.3
3.1
Item 124
0.8
1.3
3.1