Assembly
05.00 | SFL | Assembly and operating manual | en | 389398
29
Ø
Connect the sensor and fasten the cable, see the sensor's
assembly and operating manual.
Ø
Pressurize connection B until the swivel unit has reached its end
position (starting position 0°,
21]).
Ø
Push the sensor (1) into the groove until the sensor switches
and the LED lights up.
Ø
Fasten the sensor (1) in this position using a threaded pin.
Tightening torque: 10 Ncm.
Ø
Swivel the unit repeatedly back and forth and check whether
the sensor is loosing the signal and receiving it again.
Ø
If the sensor (1) does not switch when reaching the end
position, push the sensor (1) a little bit further into the groove
until it switches again.
Ø
Check the switching position and, if necessary, repeat the above
mentioned steps until the sensor switches securely when
reaching the end position even after multiple swivel
movements.
Ø
Vent connection B and pressurize connection A with
compressed air until the swivel unit has reached the end
position
- for 180° variant: end position 180°
- for 90° variant: end position 90°.
Ø
Adjust the sensor (2).