Is torque dropping?
Possible cause
Corrective action
Seals of the drive piston defective
Send the module to SCHUNK with a repair
order (recommended).
Replace the seals of the drive piston.
Positioning of the swivel table defective
Send the module to SCHUNK with a repair
order.
Compressed air lines are blocked
Check the compressed air lines for pinching
or damage.
Pressure drops below minimum.
Does the module rotate abruptly?
Possible cause
Corrective action
Seals of the drive piston defective
Send the module to SCHUNK with a repair
order (recommended).
Replace the seals of the drive piston.
Positioning of the swivel table defective
Send the module to SCHUNK with a repair
order.
Compressed air lines are blocked
Check the compressed air lines for pinching
or damage.
Does the module move hard against the end positions?
Possible cause
Corrective action
Fine adjustment of the absorber stroke is
faulty
Readjust absorber stroke.
Absorber defective
Replace and readjust absorbers.
The exhaust air throttle is defective
Replace the exhaust air throttle.
Speed of rotation too high
Setting the exhaust air throttle