Troubleshooting
30
01.01|RP / RW / RC 1212-2128|en
Troubleshooting
Modul does not move?
Possible cause
Corrective action
Base jaws jam in housing, possible cause:
bolting surface not sufficiently level.
Check the levelness of the bolting surface.
Loosen the mounting screws for the gripper
and actuate the gripper again.
Pressure drops below minimum.
Compressed air lines switched
Check compressed air lines.
Proximity switch defective or set incorrect. Repair the proximity switch.
Component is broken, e.g. through over-
loading
Replace component or send the module
with a repair order to SCHUNK. Ensure that
the module was only used within its defined
application parameters.
The module does not travel through the entire stroke?
Possible cause
Corrective action
Deposits of dirt in the mechanical elements Clean the module and relubricate it.
Pressure drops below minimum.
Check the air supply.
Mounting surface is not even enough
Check the levelness of the bolting surface.
Component is broken, e.g. through over-
loading
Send the module to SCHUNK with a repair
order or disassemble module.