Assembly and settings
01.01|RP / RW / RC 1212-2128|en
25
4 If need be, repeat the procedure with the second sensor and
the opposing piston position.
For the RMNS and RMNZ monitoring sets, the control cam inte-
grated in the rotary table is inductively monitored.
Fig. 8 RMNS-12
Proximity switch monitoring sets for:
•
RM rotary module...: RMNS-12
•
Intermediate stop, RZ...: RMNZ-12*
Scope of delivery of the monitoring sets:
•
1x retaining plate
•
2x (1x*) control cam
•
2x (1x*) proximity switch
•
2x (1x*) connection cable
Piston is at the respective end or intermediate position.
The proximity switch is set to the switching condition.
When the RMNZ is used, the cam is offset to the RMNS cam...
1 Undo the attachment screw.
2 Push the control cam in the prism slot of the rotary table until
the signal is present.
3 Fix the control cam via the attachment screw.
Attachment / ad-
justment of the
RMNS and RMNZ
monitoring sets
Setting the
monitoring
www.comoso.com
Содержание RC 1212
Страница 48: ...48 01 01 RP RW RC 1212 2128 en www comoso com ...