Assembly
28
06.00|PZB-plus |en
Flexible position sensor FPS
To use the flexible position sensor FPS-M8, the grippers have to be
retrofitted with a special mounting kit. This mounting kit is
available from SCHUNK (see catalog).
1 Remove the switching cam (21) and the screw (38) on one site
of the gripper.
2 Push the switching cam of the mouting kit (21) with the cham-
fered side first into the base jaw (2) and fasten it by tightening
the screw (38) form the mounting kit.
3 First push the spacer (26) and then the flexible position sensor
FPS M8 (15) through the bracket (17) into the hole provided in
the housing (1) to the stop and secure the sensor in this posi-
tion by tightening the screw (16).
For adjustment of the sensor see manual of the sensor.